Utah Admin. Code R315-265-1032 - Air Emission Standards for Process Vents-Standards: Process Vents
(a) The owner or operator of a facility with
process vents associated with distillation, fractionation, thin-film
evaporation, solvent extraction or air or steam stripping operations managing
hazardous wastes with organic concentrations at least 10 ppmw shall either:
(1) Reduce total organic emissions from all
affected process vents at the facility below 1.4 kg/h, 3 lb/h, and 2.8 Mg/yr,
3.1 tons/yr, or
(2) Reduce, by use
of a control device, total organic emissions from all affected process vents at
the facility by 95 weight percent.
(b) If the owner or operator installs a
closed-vent system and control device to comply with the provisions of
Subsection R315-265-1032(a), the closed-vent system and control device shall
meet the requirements of Section R315-265-1033.
(c) Determinations of vent emissions and
emission reductions or total organic compound concentrations achieved by addon
control devices may be based on engineering calculations or performance tests.
If performance tests are used to determine vent emissions, emission reductions,
or total organic compound concentrations achieved by add-on control devices,
the performance tests shall conform with the requirements of Subsection
R315-265-1034(c).
(d) If an owner
or operator and the Director do not agree on determinations of vent emissions
and emission reductions or both or total organic compound concentrations
achieved by add-on control devices based on engineering calculations, the test
methods in Subsection R315-265-1034(c) shall be used to resolve the
disagreement.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.