Utah Admin. Code R315-265-1056 - Air Emission Standards for Equipment Leaks - Standards: Open-Ended Valves or Lines

(a)
(1) Each open-ended valve or line shall be equipped with a cap, blind flange, plug, or a second valve.
(2) The cap, blind flange, plug, or second valve shall always seal the open end except during operations requiring hazardous waste stream flow through the open-ended valve or line.
(b) Each open-ended valve or line equipped with a second valve shall be operated in a manner so that the valve on the hazardous waste stream end is closed before the second valve is closed.
(c) If a double block and bleed system is being used, the bleed valve or line may remain open during operations that require venting the line between the block valves but shall comply with Subsection R315-265-1056(a) at any other time.

Notes

Utah Admin. Code R315-265-1056
Adopted by Utah State Bulletin Number 2025-02, effective 1/13/2025

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.


No prior version found.