Utah Admin. Code R315-265-225 - Surface Impoundments - Waste Analysis and Trial Tests
(a) In addition to the waste analyses
required by Section R315-265-13, whenever a surface impoundment is to be used
to:
(1) Chemically treat a hazardous waste
which is substantially different from waste previously treated in that
impoundment; or
(2) Chemically
treat hazardous waste with a substantially different process than any
previously used in that impoundment; the owner or operator shall, before
treating the different waste or using the different process:
(i) Conduct waste analyses and trial
treatment tests, for example, bench scale or pilot plant scale tests;
or
(ii) Obtain written, documented
information on similar treatment of similar waste under similar operating
conditions; to show that this treatment will comply with Subsection
R315-265-17(b).
Comment: As required by Section R315-265-13, the waste analysis plan shall include analyses needed to comply with Sections R315-265-229 and 265-230. As required by Section R315-265-73, the owner or operator shall place the results from each waste analysis and trial test, or the documented information, in the operating record of the facility.