Utah Admin. Code R315-265-253 - Waste Piles - Containment
If leachate or run-off from a pile is a
(a)
(1) The pile shall be placed on an
impermeable base that is compatible with the waste under the conditions of
treatment or storage;
(2) The owner
or operator shall design, construct, operate, and maintain a run-on control
system capable of preventing flow onto the active portion of the pile during
peak discharge from at least a 25-year storm;
(3) The owner or operator shall design,
construct, operate, and maintain a run-off management system to collect and
control at least the water volume resulting from a 24-hour, 25-year storm;
and
(4) Collection and holding
facilities, for example, tanks or basins, associated with run-on and run-off
control systems shall be emptied or otherwise managed expeditiously to maintain
design capacity of the system; or
(b)
(1) The
pile shall be protected from precipitation and run-on by some other means;
and
(2) No liquids or wastes
containing free liquids may be placed in the pile.
Comment: If collected leachate or run-off is discharged
through a point source to waters of the United States, it is subject to the
requirements of section 402 of the Clean Water
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.