Utah Admin. Code R315-265-259 - Waste Piles - Response Actions
(a) The
owner or operator of waste pile units subject to Section R315-265-254 shall
develop and keep on-site until closure of the facility a response action plan.
The response action plan shall set forth the actions to be taken if the action
leakage rate has been exceeded. At a minimum, the response action plan shall
describe the actions specified in Subsection R315-265-259(b).
(b) If the flow rate into the leak
determination system exceeds the action leakage rate for any sump, the owner or
operator shall:
(1) Notify the Director in
writing of the exceedance within seven days of the determination;
(2) Submit a preliminary written assessment
to the Director within 14 days of the determination, as to the amount of
liquids, likely sources of liquids, possible location, size, and cause of any
leaks, and short-term actions taken and planned;
(3) Determine to the extent practicable the
location, size, and cause of any leak;
(4) Determine whether waste receipts should
cease or be curtailed, whether any waste should be removed from the unit for
inspection , repairs, or controls, and whether or not the unit should be
closed;
(5) Determine any other
short-term and longer-term actions to be taken to mitigate or stop any leaks;
and
(6) Within 30 days after the
notification that the action leakage rate has been exceeded, submit to the
Director the results of the analyses specified in Subsections
R315-265-259(b)(3), (4), and (5), the results of actions taken, and actions
planned. Monthly thereafter, as long as the flow rate in the leak detection
system exceeds the action leakage rate, the owner or operator shall submit to
the Director a report summarizing the results of any remedial actions taken and
actions planned.
(c) To
make the either the leak or remediation or both determinations in Subsections
R315-265-259(b)(3), (4), and (5), the owner or operator shall:
(1)
(i)
Assess the source of liquids and amounts of liquids by source,
(ii) Conduct a fingerprint, hazardous
constituent, or other analyses of the liquids in the leak detection system to
identify the source of liquids and possible location of any leaks, and the
hazard and mobility of the liquid; and
(iii) Assess the seriousness of any leaks in
terms of potential for escaping into the environment; or
(2) Document why such assessments are not
needed.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.