Utah Admin. Code R315-265-303 - Landfills - Response Actions
(a) The
owner or operator of landfill units subject to Subsection R315-265-301(a) shall
develop and keep on site until closure of the facility a response action plan.
The response action plan shall set forth the actions to be taken if the action
leakage rate has been exceeded. At a minimum, the response action plan shall
describe the actions specified in Subsection R315-265-303(b).
(b) If the flow rate into the leak detection
system exceeds the action leakage rate for any sump, the owner or operator
shall:
(1) notify the director in writing of
the exceedance within seven days of the determination;
(2) submit a preliminary written assessment
to the director within 14 days of the determination, as to the amount of
liquids, likely sources of liquids, possible location, size, and cause of any
leaks, and short-term actions taken and planned;
(3) determine to the extent practicable the
location, size, and cause of any leak;
(4) determine whether waste receipt should
stop or be curtailed, whether any waste should be removed from the unit for
inspection, repairs, or controls, and whether or not the unit should be
closed;
(5) determine any other
short-term and longer-term actions to be taken to mitigate or stop any leaks;
and
(6) within 30 days after the
notification that the action leakage rate has been exceeded, submit to the
director the results of the analyses specified in Subsections
R315-265-303(b)(3), R315-265-303(b)(4), and R315-265-303(b)(5), the results of
actions taken, and actions planned. Monthly thereafter, as long as the flow
rate in the leak detection system exceeds the action leakage rate, the owner or
operator shall submit to the director a report summarizing the results of any
remedial actions taken and actions planned.
(c) To make the leak or remediation
determinations or both in Subsections R315-265-303(b)(3), R315-265-303(b)(4),
and R315-265-303(b)(5), the owner or operator shall:
(1)
(i)
assess the source of liquids and amounts of liquids by source;
(ii) conduct a fingerprint, hazardous
constituent, or other analyses of the liquids in the leak detection system to
identify the source of liquids and possible location of any leaks, and the
hazard and mobility of the liquid; and
(iii) assess the seriousness of any leaks in
terms of potential for escaping into the environment; or
(2) document why the assessments are not
needed.