Utah Admin. Code R315-265-92 - Ground-Water Monitoring - Sampling and Analysis
(a) The owner or operator shall obtain and
analyze samples from the installed ground-water monitoring system. The owner or
operator shall develop and follow a ground-water sampling and analysis plan. He
shall keep this plan at the facility . The plan shall include procedures and
techniques for:
(1) Sample
collection;
(2) Sample preservation
and shipment;
(3) Analytical
procedures; and
(4) Chain of
custody control.
Comment: See "Procedures Manual For Ground-water
(b) The owner or operator shall determine the
concentration or value of the following parameters in ground-water samples in
accordance with Subsections R315-265-92(c) and (d):
(1) Parameters characterizing the suitability
of the ground water as a drinking water supply, as specified in Appendix III to
40 CFR 265, which is adopted and incorporated by reference.
(2) Parameters establishing ground-water
quality:
(i) Chloride
(ii) Iron
(iii) Manganese
(iv) Phenols
(v) Sodium
(vi) Sulfate
Comment: These parameters are to be used as a basis for comparison in the event a ground-water quality assessment is required under Subsection R315-265-93(d).
(3) Parameters used as indicators of
ground-water contamination:
(i) pH
(ii) Specific Conductance
(iii) Total Organic Carbon
(iv) Total Organic Halogen
(c)
(1) For all monitoring wells, the owner or
operator shall establish initial background concentrations or values of all
parameters specified in Subsection R315-265-92(b). He shall do this quarterly
for one year .
(2) For each of the
indicator parameters specified in Subsection R315-265-92(b)(3), at least four
replicate measurements shall be obtained for each sample and the initial
background arithmetic mean and variance shall be determined by pooling the
replicate measurements for the respective parameter concentrations or values in
samples obtained from upgradient wells during the first year .
(d) After the first year , all
monitoring wells shall be sampled and the samples analyzed with the following
frequencies:
(1) Samples collected to
establish ground-water quality shall be obtained and analyzed for the
parameters specified in Subsection R315-265-92(b)(2) at least
annually.
(2) Samples collected to
indicate ground-water contamination shall be obtained and analyzed for the
parameters specified in Subsection R315-265-92(b)(3) at least
semi-annually.
(e)
Elevation of the ground-water surface at each monitoring well shall be
determined each time a sample is obtained.