Utah Admin. Code R315-270-18 - Hazardous Waste Permit Program - Specific Part B Information Requirements for Waste Piles
Except as otherwise provided in Section R315-264-1, owners and operators of facilities that store or treat hazardous waste in waste piles shall provide the following additional information:
(a) A list of hazardous wastes placed or to
be placed in each waste pile;
(b)
If an exemption is sought to Section
R315-264-251
and Sections
R315-264-90
through 101 as provided by Subsection
R315-264-250(c)
or Subsection
R315-264-90(b)(2),
an explanation of how the standards of Subsection
R315-264-250(c)
will be complied with or detailed plans and an engineering report describing
how the requirements of Subsection
R315-264-90(b)(2)
will be met.
(c) Detailed plans and
an engineering report describing how the waste pile is designed and is or will
be constructed, operated, and maintained to meet the requirements of Sections
R315-264-19
and R315-264-251thRough 253, addressing the following items:
(1)
(i) The
liner system, except for an existing portion of a waste pile, if the waste pile
shall meet the requirements of Subsection
R315-264-251(a).
If an exemption from the requirement for a liner is sought as provided by
Subsection
R315-264-251(b),
submit detailed plans, and engineering and hydrogeological reports, as
appropriate, describing alternate designs and operating practices that will, in
conjunction with location aspects, prevent the migration of any hazardous
constituents into the ground water or surface water at any future
time;
(ii) The double liner and
leak, leachate, detection; collection; and removal system, if the waste pile
shall meet the requirements of Subsection
R315-264-251(c).
If an exemption from the requirements for double liners and a leak detection,
collection, and removal system or alternative design is sought as provided by
Subsections
R315-264-251(d),
(e), or (f), submit appropriate
information;
(iii) If the leak
detection system is located in a saturated zone, submit detailed plans and an
engineering report explaining the leak detection system design and operation,
and the location of the saturated zone in relation to the leak detection
system;
(iv) The construction
quality assurance (CQA) plan if required under Section
R315-264-19;
(v) Proposed action leakage rate, with
rationale, if required under Section
R315-264-252,
and response action plan, if required under Section
R315-264-253;
(2) Control of run-on;
(3) Control of run-off;
(4) Management of collection and holding
units associated with run-on and run-off control systems; and
(5) Control of wind dispersal of particulate
matter, where applicable;
(d) A description of how each waste pile,
including the double liner system, leachate collection and removal system, leak
detection system, cover system, and appurtenances for control of run-on and
run-off, will be inspected in order to meet the requirements of Subsections
R315-264-254(a), (b),
and (c). This information shall be included
in the inspection plan submitted under Subsection
R315-270-14(b)(5);
(e) If treatment is carried out on or in the
pile, details of the process and equipment used, and the nature and quality of
the residuals;
(f) If ignitable or
reactive wastes are to be placed in a waste pile, an explanation of how the
requirements of Section
R315-264-256
will be complied with;
(g) If
incompatible wastes, or incompatible wastes and materials will be placed in a
waste pile, an explanation of how Section
R315-264-257
will be complied with;
(h) A
description of how hazardous waste residues and contaminated materials will be
removed from the waste pile at closure, as required under Subsection
R315-264-258(a).
For any waste not to be removed from the waste pile upon closure, the owner or
operator shall submit detailed plans and an engineering report describing how
Subsections
R315-264-310(a) and
(b) will be complied with. This information
should be included in the closure plan and, where applicable, the post-closure
plan submitted under Subsection
R315-270-14(b)(13).
(i) A waste management plan for EPA Hazardous
Waste Nos. FO20, FO21, FO22, FO23, FO26, and FO27 describing how a waste pile
that is not enclosed, as defined in Section
R315-264-250(c),
is or will be designed, constructed, operated, and maintained to meet the
requirements of Section
R315-264-259.
This submission shall address the following items as specified in Section
R315-264-259:
(1) The volume, physical, and chemical
characteristics of the wastes to be disposed in the waste pile, including their
potential to migrate through soil or to volatilize or escape into the
atmosphere;
(2) The attenuative
properties of underlying and surrounding soils or other materials;
(3) The mobilizing properties of other
materials co-disposed with these wastes; and
(4) The effectiveness of additional
treatment, design, or monitoring techniques.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.