Utah Admin. Code R315-270-20 - Hazardous Waste Permit Program - Specific Part B Information Requirements for Land Treatment Facilities
Except as otherwise provided in Section R315-264-1, owners and operators of facilities that use land treatment to dispose of hazardous waste shall provide the following additional information:
(a) A description of plans to conduct a
treatment demonstration as required under Section
R315-264-272.
The description shall include the following information;
(1) The wastes for which the demonstration
will be made and the potential hazardous constituents in the waste;
(2) The data sources to be used to make the
demonstration, e.g., literature, laboratory data, field data, or operating
data;
(3) Any specific laboratory
or field test that will be conducted, including:
(i) The type of test, e.g., column leaching,
degradation;
(ii) Materials and
methods, including analytical procedures;
(iii) Expected time for completion;
(iv) Characteristics of the unit that will be
simulated in the demonstration, including treatment zone characteristics,
climatic conditions, and operating practices.
(b) A description of a land treatment
program, as required under Section
R315-264-271.
This information shall be submitted with the plans for the treatment
demonstration, and updated following the treatment demonstration. The land
treatment program shall address the following items:
(1) The wastes to be land treated;
(2) Design measures and operating practices
necessary to maximize treatment in accordance with Subsection
R315-264-273(a)
including:
(i) Waste application method and
rate;
(ii) Measures to control soil
pH;
(iii) Enhancement of microbial
or chemical reactions;
(iv) Control
of moisture content;
(3)
Provisions for unsaturated zone monitoring, including:
(i) Sampling equipment, procedures, and
frequency;
(ii) Procedures for
selecting sampling locations;
(iii)
Analytical procedures;
(iv) Chain
of custody control;
(v) Procedures
for establishing background values;
(vi) Statistical methods for interpreting
results;
(vii) The justification
for any hazardous constituents recommended for selection as principal hazardous
constituents, in accordance with the criteria for such selection in Subsection
R315-264-278(a);
(4) A list of hazardous constituents
reasonably expected to be in, or derived from, the wastes to be land treated
based on waste analysis performed pursuant to Section
R315-264-13;
(5) The proposed dimensions of the treatment
zone;
(c) A description
of how the unit is or will be designed, constructed, operated, and maintained
in order to meet the requirements of Section
R315-264-273.
This submission shall address the following items:
(1) Control of run-on;
(2) Collection and control of
run-off;
(3) Minimization of
run-off of hazardous constituents from the treatment zone;
(4) Management of collection and holding
facilities associated with run-on and run-off control systems;
(5) Periodic inspection of the unit. This
information should be included in the inspection plan submitted under
Subsection
R315-270-14(b)(5);
(6) Control of wind dispersal of particulate
matter, if applicable;
(d) If food-chain crops are to be grown in or
on the treatment zone of the land treatment unit, a description of how the
demonstration required under Subsection
R315-264-276(a)
will be conducted including:
(1)
Characteristics of the food-chain crop for which the demonstration will be
made.
(2) Characteristics of the
waste, treatment zone, and waste application method and rate to be used in the
demonstration;
(3) Procedures for
crop growth, sample collection, sample analysis, and data evaluation;
(4) Characteristics of the comparison crop
including the location and conditions under which it was or will be grown;
(e) If food-chain crops
are to be grown, and cadmium is present in the land-treated waste, a
description of how the requirements of Subsection
R315-264-276(b)
will be complied with;
(f) A
description of the vegetative cover to be applied to closed portions of the
facility, and a plan for maintaining such cover during the post-closure care
period, as required under Subsections
R315-264-280(a)(8)
and
R315-264-280(c)(2).
This information should be included in the closure plan and, where applicable,
the post-closure care plan submitted under Subsection
R315-270-14(b)(13);
(g) If ignitable or reactive
wastes will be placed in or on the treatment zone, an explanation of how the
requirements of Section
R315-264-281
will be complied with;
(h) If
incompatible wastes, or incompatible wastes and materials, will be placed in or
on the same treatment zone, an explanation of how Section
R315-264-282
will be complied with.
(i) A waste
management plan for EPA Hazardous Waste Nos. FO20, FO21, FO22, FO23, FO26, and
FO27 describing how a land treatment facility is or will be designed,
constructed, operated, and maintained to meet the requirements of Section
R315-264-283.
This submission shall address the following items as specified in Section
R315-264-283:
(1) The volume, physical, and chemical
characteristics of the wastes, including their potential to migrate through
soil or to volatilize or escape into the atmosphere;
(2) The attenuative properties of underlying
and surrounding soils or other materials;
(3) The mobilizing properties of other
materials co-disposed with these wastes; and
(4) The effectiveness of additional
treatment, design, or monitoring techniques.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.