Utah Admin. Code R315-303-2 - Standards for Performance
(1) Ground
Water. An owner or operator of a disposal facility shall not contaminate the
ground water underlying the facility beyond the ground water quality standard
set in Section
R315-308-4
or, for constituents not set in Section
R315-308-4,
as established by the Director based on health risk standards.
(2) Air Quality and Explosive Gas Emissions.
(a) An owner or operator of a disposal
facility shall not allow concentrations of explosive gases generated by the
facility to exceed:
(i) twenty-five percent
of the lower explosive limit for explosive gases in facility structures,
excluding gas control or recovery system components; and
(ii) the lower explosive limit for explosive
gases at the property boundary or beyond.
(b) An owner or operator of a disposal
facility shall not cause a violation of any ambient air quality standard at the
property boundary or emission standard from any emission of landfill gases,
combustion or any other emission associated with the facility.
(3) Surface Waters. An owner or
operator of a disposal facility:
(a) shall
not cause a violation of any Utah Pollution Discharge Elimination System permit
or standard from discharges of surface run-off, leachate or any liquid
associated with the facility; and
(b) shall be in compliance under the Clean
Water Act for any discharge as well as in compliance with any area-wide or
state-wide plan under Section 208 or 319 of the Clean Water Act.