3.1 All vault privies shall have vaults or
receptacles which are watertight and shall be constructed of reinforced
concrete, metal or other material of equal durability which has been approved
by the local health department. Inside and outside surfaces of metal vaults
shall be thoroughly coated with a good quality asphalt-base material.
3.2 For all earthen pit privies, pit cribbing
shall be installed in the pit to prevent caving of soil into the pit and to
insure a firm foundation for the building. The pit cribbing shall fit firmly,
be in uniform contact with the earth walls on all sides, and shall descend to
the full depth of the pit and rise flush with the ground surface.
3.3 All vault privies and earthen pit privies
shall comply with the following:
A. A sill or
foundation constructed of concrete or treated lumber shall be placed on the
ground surface around the vault or pit so as to underlie the floor area of the
privy building.
B. A floor and
riser of impervious material shall be placed over the sill and vault or pit in
such a manner to prevent access of rodents and insects into the vault or
pit.
C. The privy building shall be
firmly anchored, rigidly constructed, free from hostile surface features such
as sharp edges and exposed nail points, and shall afford complete privacy and
protection from the elements. The building shall be of fly-tight construction.
The door(s) shall be self-closing and provided with an inside latch. Interior
floors, walls, ceilings, partitions, and doors shall be finished with readily
cleanable materials resistant to wastes and cleaners.
D. The building shall be ventilated by
leaving approximately 4-inch openings at (1) the top of two opposite walls just
beneath the roof, and (2) at the bottom of two opposite walls just above the
floor, all of which are screened with 16-mesh screen or smaller of durable
material. Hardware mesh with 1/4" openings may be placed on the inside and
outside of the screened openings to protect the smaller mesh screen. Direct
line of sight into the building through the bottom ventilation openings shall
be effectively obstructed with a louver or other suitable means.
E. Each vault or pit shall be vented to
atmosphere with a minimum of 100 square inches of vent area for each seat
connected to the vault. (One hundred square inches is equivalent to two 8-inch
pipes, or one 12-inch pipe.) Roof vents must extend at least 12 inches above
the highest point of the roof and shall be provided with a rain cap and
screened with 16-mesh screen or smaller of durable material. Venting to an
attic vent may be provided for by utilizing the space between an inside and
outside wall if that space provides sufficient area.
F. The seat should be so spaced as to provide
a minimum clear space of 24 inches between each seat opening in multiple unit
installations, and should provide 12 inches clear space from the seat opening
to the sidewall in single and multiple units. In multiple unit installations,
partitions should be provided between risers to afford user privacy.
G. The seat riser should have an inside
clearance of not less than 21 inches from the front wall and not less than 24
inches from the rear wall of the privy building.
H. The seat top should be not less than 12
inches nor more than 16 inches above the floor.
I. The seat opening shall be covered with an
attached, movable toilet seat and lid of easily cleanable, impervious material
that can be raised to allow sanitary use as a urinal and can be closed when not
in use. Privy buildings for public use shall be provided with open-front
seats.
J. Commercially
preconstructed vault privy buildings not incorporating all of the requirements
of these rules may be evaluated for approval on a case-by-case basis by local
health departments.