A. Guardrails, Handrails and Covers.
1. Guarding of Floor Openings and Floor
Holes.
Floor openings and floor holes shall be guarded by a standard railing and toeboards and/or cover.
2. Guarding of Wall Openings.
Wall openings from which there is a drop of more than 4 feet shall be guarded.
3.
Guarding of Open-Sided Floors, Platforms, and Runways
a. Every open-sided floor or platform 4 feet
or more above adjacent floor or ground level shall be guarded by a standard
railing, or equivalent.
b. Standard
railing shall be provided on the inside of all mud tank runways unless other
means are available to prevent an employee from falling into the mud
tanks.
c. Regardless of height,
open-sided floors, walkways, platforms, or runways above or adjacent to
dangerous equipment and similar hazards shall be guarded with a standard
railing and toeboard.
4.
Stairway Railings and Guards.
Every flight of stairs having four or more risers shall be equipped with standard stair railings on open sides.
B. Floors, Stairways, and
Platforms.
1. Floors, stairways, and platforms
shall be free of dangerous projections or obstructions and shall be maintained
in good repair and reasonably free from oil, grease, water, or other materials
of similar nature. Where the type of operation necessitates working on slippery
floor areas, such surfaces shall be protected against slipping by the use of
mats, grates, cleats, or other methods to provide reasonable
protection.
2. Each corner of a
crown block shall be securely bolted or welded to the mast or
derrick.
3. Each finger of a finger
board shall be bolted or welded to its support beam.
4. Any temporary stabbing board or other
temporary boards placed in the derrick shall be securely fastened.
5. On all derricks, ladder platforms shall be
installed adjacent to, and shall provide safe access to the work
platforms.
6. Ladder platforms are
to be located at the crown of all drilling rigs.
7. With the exception of the stabbing board
and derrick board, every platform erected on the inside of a derrick shall
completely cover the space from the working edge of the platform back to the
legs and girts of the derrick.
C. Exits, Access, and Egress.
1. Exits shall be provided to the outside on
at least 3 sides of the derrick floor.
2. All work stations shall have two means of
egress, except for hopper house.
3.
No exit door of the derrick floor, including all doors of the doghouse, shall
be held closed with a lock or outside latch while anyone is on the derrick
floor.
4. No employee shall slide
down any pipe, kelly hose, cable, or rope line except in the event of an
extreme emergency.
5. No employee
shall use the catline as a means of ascending to or descending from any point
in the derrick except in an emergency. Even then, the rotary table shall be
locked out and qualified employees shall operate the cathead and
controls.