Utah Admin. Code R652-122-1500 - Minimum Standards for Wildland Firefighting Equipment
|
TABLE 1 Engines |
|||
|
Component |
Type 1 |
Type 2 |
Type 3 |
|
Pump Rating - gpm |
1,000+ @ 150 psi |
250+ @ 150 psi |
150+ @ 250 psi |
|
Tank Capacity - gal |
400+ |
400+ |
500+ |
|
Hose 2.5 inch |
1,200 ft |
1,000 ft |
-- |
|
Hose 1.5 inch |
400 ft |
500 ft |
500 ft |
|
Hose 1 inch |
-- |
-- |
500 ft |
|
Ladders |
48 ft |
48 ft |
-- |
|
Master Stream -- gpm |
500 |
-- |
-- |
|
Personnel - minimum |
4 |
3 |
2 |
|
Component |
Type 4 |
Type 5 |
Type 6 |
|
Pump Rating - gpm |
50 @ 100 psi |
50 @ 100 psi |
30 @ 100 psi |
|
Tank Capacity - gal |
750+ |
400 - 750 |
150 - 400 |
|
Hose 2.5 inch |
-- |
-- |
-- |
|
Hose 1.5 inch |
300 ft |
300 ft |
300 ft |
|
Hose 1 inch |
300 ft |
300 ft |
300 ft |
|
Ladders |
-- |
-- |
-- |
|
Master Stream -- gpm |
-- |
-- |
-- |
|
Personnel -minimum |
2 |
2 |
2 |
|
TABLE 2 Water Tenders |
|||
|
Component |
Type 1 |
Type 2 |
Type 3 |
|
Tank Capacity - gal |
5,000+ |
2,500+ |
1,000+ |
|
Pump Capacity - gpm |
300+ |
200+ |
200+ |
|
Off Load Capacity - gpm |
300+ |
200+ |
200+ |
|
Max Refill Time -- min |
30 |
20 |
15 |
|
Personnel tactical/nontactical |
2/1 |
2/1 |
2/1 |