Utah Admin. Code R920-50-2 - Definitions
In addition to terms defined in Section 72-11-102, the following terms are defined:
(1)
"Aerial lift specialist" as used in American National Standards Institute
(ANSI) B77.1 Sections 3.3.4.1 and 4.3.4.1, means a Ropeway Inspector as defined
in Subsection
R920-50-3(32).
(2) "Aerial tramway specialist" as used in
ANSI B77.1 Section 2.3.4.1 means a Ropeway Inspector as defined in Subsection
R920-50-3(32).
(3) "Air Space" means the area bounded by
vertical planes commencing at a point 35 feet from the intersection of the
vertical planes of the ropes and ground surface.
(4) "Annual general inspection" means an
inspection of a passenger ropeway made by a Ropeway Inspector to verify
preservation of original design integrity and to determine that components and
systems of the passenger ropeway are in proper working order and in accordance
with this rule.
(5) "Audible
warning devices" means an audible warning device that signals an impending
start of the aerial lift.
(6)
"Auxiliary Power Unit" is a generic term to describe a gas or diesel engine
generally used as a backup to the prime mover.
(7) "Bullwheel" means a large grooved wheel
at a terminal that rotates continuously when the haul rope is moving and
deflects the haul rope by an angle of ten degrees or more.
(8) "Carrier" means the structural and
mechanical assemblage in or on which passengers or freight of a ropeway system
are transported. Unless qualified, the carrier includes, for example, the
carriage, grip or clip, hanger, and cabin or chair.
(9) "Conveyor specialist" as used in ANSI
B77.1 Section 7.3.4 means a Ropeway Inspector as defined in Subsection
R920-50-3(32).
(10) "Dynamic Testing Logs" means a record of
the data collected during the dynamic test.
(11) "Experienced personnel" means an
individual who has acquired knowledge and skills through study, training, or
experience in ropeway maintenance, operation, or testing.
(12) "Existing ropeway" means any passenger
ropeway that has been operated for passengers for more than one calendar
year.
(13) "Funicular specialist"
as used in American National Standards Institute (ANSI) B77.2 Section 2.3.4.1
means a Ropeway Inspector as defined in Subsection
R920-50-3(32).
(14) "Grip" means the device by which
carriers are attached to the haul rope.
(15) "Governing Standard" means the ANSI B77
standard that is incorporated by reference as part of Section
R920-50-3.
(16) "Haul rope" means a wire rope used on a
ropeway that provides motion to carrier and is powered by the drive
bullwheel.
(17) "Incident
inspection" means an inspection of a passenger ropeway incident made by an
approved Ropeway Inspector or a qualified engineer at the request of the
Committee.
(18) "Land surveyor"
means an individual licensed under Section
58-22-102
as a professional land surveyor.
(19) "Modification" means any change as
defined in ANSI B77.1 Section 1.2.4.4, ANSI B77.2 Section 1.2.4.4, and the
replacement of a ropeway component by one that alters the certified design or
construction provided by the passenger ropeway manufacturer or
designer.
(20) "New ropeway" means
any passenger ropeway registered for the first time for passenger operation
during its first calendar year of operation.
(21) "Operational inspection" means an
inspection of a passenger ropeway made by a Ropeway Inspector to determine
compliance with the operation and maintenance requirements of the Governing
Standard and with this rule.
(22)
"Operating personnel" means persons employed by the operator to supervise the
operation, or engaged in servicing, checking, inspecting or maintaining the
machinery or structures of a ropeway and when on duty for such purposes on that
ropeway.
(23) "Passenger" means any
person riding a ropeway, other than "operating personnel."
(24) "Passenger Ropeway Incident" means:
(a) a structural, mechanical, or electrical
malfunction or failure of a passenger ropeway component that results in bodily
injury to any person on, or inside the load or unload zone of, a passenger
ropeway;
(b) a deropement
regardless of whether the passenger ropeway is evacuated;
(c) an evacuation of the passenger ropeway
other than by prime mover or auxiliary power unit, regardless of
cause;
(d) a fire involving a
passenger ropeway component or adjacent structure;
(e) a structural, mechanical, or electrical
malfunction or failure of a passenger ropeway component that results in a
ropeway that will not SLOW DOWN when given the command to do so, will not STOP
when given the command to do so, OVERSPEEDS beyond control settings or both
maximum design speed, ACCELERATES faster than normal design acceleration,
SELF-STARTS or SELF-ACCELERATES without the command to do so, REVERSES
direction unintentionally and without the command to do so , or a loss of
control of the passenger ropeway as defined in ANSI B77.2 Section
2.2.3.1;
(f) a wire rope damage
which exceeds the requirement in ANSI B77.1 Section A.4.1.3 or ANSI B77.2
Section A.4.1; and
(g) a
structural, mechanical, or electrical malfunction or failure of a passenger
ropeway component or its primary connection that has the apparent potential for
causing bodily injury to any person, including the following:
(i) Terminal Structure;
(ii) Bullwheel;
(iii) Brake System;
(iv) Tower Structure;
(v) Sheave, Axle, or Sheave
Assembly;
(vi) Carrier;
or
(vii) Grip.
(25) "Portable Ropeway" means a
ropeway expressly designed to be portable, operated without a permanent
foundation, and that has a design range of maximum grade.
(26) "Pre-operational inspection" means an
inspection made by a Ropeway Inspector before the operation of any new or
modified passenger ropeway requiring an Acceptance Inspection and Test.
(27) "Qualified engineer" means
any engineer who is licensed to practice engineering in Utah and who has been
approved by the Committee.
(28)
"Prime Mover" means the power unit utilized for the continuous operation of a
passenger ropeway.
(29) "Qualified
personnel" as used in ANSI B77.1 Sections 2.1.1.11, 3.1.1.11, 4.1.1.11,
5.1.1.11, 6.1.1.11, and 7.1.1.11 means a qualified engineer as defined by
Subsection
R920-50-3(27).
(30) "Relocated ropeway" means any passenger
ropeway moved to a new location.
(31) "Responsible charge" means effective
control and direction of the installation or modification of a passenger
ropeway.
(32) "Ropeway Inspector"
means an engineer licensed to practice engineering in Utah, independent of the
ropeway owner, and approved by the Committee to inspect passenger
ropeways.
(33) "Sheave" means
pulley or wheel grooved for haul rope.
(34) "Structure" means any edifice, including
residential and public buildings, or any other structure or equipment that
could reasonably be expected to interfere with the safe operation of a ropeway.
Ropeway components required for the operation of the ropeway are not
structures.
(35) "Surface lift
specialist" as used in ANSI B77.1 Section 5.3.4.1, means a Ropeway Inspector as
defined in Subsection
R920-50-3(32).
(36) "Tow specialist" as used in ANSI B77.1
Section 6.3.4 means a Ropeway Inspector as defined by Subsection
R920-50-3(32).