4 Va. Admin. Code § 25-40-920 - Electric detonators
A. When
electric detonators are used, an acceptable blaster's galvanometer or blaster's
multi-meter shall be used to test detonators, firing lines, series circuits,
and total circuit resistance prior to firing.
B. Electric detonators of different brands
shall not be used in the same blast.
C. Except when being tested with an
acceptable instrument:
1. Electric detonators
shall be kept shunted until they are connected into the series
circuit;
2. Series circuits shall
be kept shunted until they are connected onto the firing line; and
3. Firing lines shall be kept shunted until
immediately before blasting.
D. Blasting machines or other acceptable
power sources shall be suitable for the number of electric detonators to be
fired and for the type of circuits to be used.
E. When electric detonators are used, sources
of stray current to the blasting area shall be de-energized. Blasting
activities shall be stopped immediately if stray current or static electricity
in amounts sufficient to cause a premature detonation are
encountered.
Notes
Statutory Authority
§§ 45.1-161.3, 45.1-161.294 and 45.1-161.305 of the Code of Virginia.