Wash. Admin. Code § 16-202-1012 - What measures must be used to prevent backflow into the irrigation water source?
Backflow prevention is a requirement on all irrigation systems used for chemigation, except when alternative technology is applied.
(1) Pressurized irrigation
system.
(a) At least one irrigation mainline
check valve must be correctly installed, properly operated, and adequately
maintained to prevent contamination of the water source. The check valve must
be located upstream from the injection point. The check valve must be
automatic, quick-closing, and capable of forming and maintaining a watertight
seal.
(b) An inspection port or a
direct access point must be positioned immediately upstream of the check valve
to allow visual and manual inspection of the check valve and the low pressure
drain. The inspection port or access point must have a minimum diameter of four
inches. If a four-inch inspection port or access point is not feasible, an
alternative access system must be devised.
(c) An inspection port or access point is not
required with an approved backflow prevention assembly.
(d) A vacuum relief valve must be located
upstream of the irrigation line check valve, installed at the top of the
irrigation pipeline, and adequately sized to prevent backsiphoning. The orifice
size must comply with current American Society of Agricultural Engineers (ASAE)
standards.
(e) An automatic low
pressure drain or similar mechanism must be placed upstream of the irrigation
line check valve and at the lowest point in the bottom of the pipeline. The low
pressure drain must be of adequate size and properly positioned to intercept
and purge leakage away from the water source.
(f) Product-treated water cannot be
discharged through a water outtake.
(2) Nonpressurized water delivery system.
(a) An open surface water delivery system
cannot be used for product application unless allowed by the label.
(b) System design must prevent the
introduction of treated water into the water source.
(c) Backflow prevention may be achieved with
a hydraulic discontinuity in source water flow or by a sufficient hydraulic
gradient.
(d) Backflow devices for
nonpressurized systems may include a weir box, drop structure, ASAE approved
air gap, batch tank, or similar device that can function to prevent backflow
into the source water.
(e)
Injection must occur downstream from the water diversion point.
(3) Cross-connection to municipal
or public water system.
Backflow prevention devices must be approved by the Washington state department of health in accordance with WAC 246-290-490.
Notes
Statutory Authority: Chapters 15.54, 15.58, 17.21, and 34.05 RCW. 01-23-018, § 16-202-1012, filed 11/9/01, effective 11/9/01.