Wash. Admin. Code § 296-155-697 - Requirements for masonry construction
(1) You must establish a limited access zone
whenever a masonry wall is being constructed. The limited access zone must
conform to the following:
(2) You
must establish the limited access zone prior to the start of construction of
the wall.
(3) The limited access
zone must be equal to the height of the wall to be constructed plus 4 feet, and
must run the entire length of the wall.
(4) You must establish the limited access
zone on the side of the wall which will be unscaffolded.
(5) You must restrict entry into the limited
access zone to only employees actively engaged in constructing the wall. You
must not permit any other employees to enter the zone.
(6) The limited access zone must remain in
place until the wall is adequately supported to prevent overturning and to
prevent collapse unless the height of wall is over 8 feet, in which case, the
limited access zone must remain in place until the requirements of subsection
(7) of this section have been met.
(7) All masonry walls over 8 feet in height
must be adequately braced to prevent overturning and to prevent collapse unless
the wall is adequately supported so that it will not overturn or collapse. The
bracing must remain in place until permanent supporting elements of the
structure are in place.
(8)
Employees engaged in cutting or chipping must wear suitable eye protection in
accordance with WAC
296-155-215.
(9) You must construct, guard, and operate
masonry saws in accordance with WAC
296-155-367(1) through
(4).
(10) Persons charged with operation of
derricks used for stone setting must be qualified in that type of
work.
(11) Stone must be set
directly on the wall by the derrick.
(12) Breast derricks when used in setting
stone must be secured against a slip or kick back and guyed with wire cables.
Provide hold down line to prevent derrick from falling back.
(13) Stone cutters must wear goggles while
trimming stone or cutting holes.
(14) You must test pins for security before
stone is hoisted.
(15) You must
protect hoisting cables from chafing and wearing over corners.
(16) Mason's mortar mixers must have a
bar-type grill installed over the mixer opening. The guard must be installed
with an automatic disconnect switch to stop the mixer tub rotation and prevent
the mixer from starting whenever the guard is not in place.