Wis. Admin. Code Department of Natural Resources NR 270.032 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT)
Except as provided in ss. NR 270.0015, 270.002 and 270.003 and 40 CFR 125.30- 125.32, any existing point source subject to this subcategory shall achieve the following effluent limitations representing the degree of effluent reduction attainable after application of the best practicable control technology currently available (BPT):
|
Effluent characteristic |
[BPT] Effluent limitations |
|
|
Maximum for any 1 day |
Average of daily values for 30 consecutive days |
|
|
Milligrams per liter |
||
|
TSS |
30.0 |
20.0 |
|
COD |
200.0 |
100.0 |
|
Zn |
1.0 |
0.5 |
|
Ra2261 (dissolved) |
10.0 |
3.0 |
|
Ra2261 (total) |
30.0 |
10.0 |
|
U |
4.0 |
2.0 |
|
pH |
(2) |
(2) |
1 Values in picocuries per liter (pCi/1).
2 Within the range 6.0 to 9.0.
|
Effluent characteristic |
[BPT] Effluent limitations |
|
|
Maximum for any 1 day |
Average of daily values for 30 consecutive days |
|
|
Milligrams per liter |
||
|
TSS |
30.0 |
20.0 |
|
COD |
- |
500.0 |
|
As |
1.0 |
0.5 |
|
Zn |
1.0 |
0.5 |
|
Ra2261 (dissolved) |
10.0 |
3.0 |
|
Ra2261 (total) |
30.0 |
10.0 |
|
NH3 |
- |
100.0 |
|
pH |
(2) |
(2) |
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.