Wis. Admin. Code Department of Natural Resources NR 809.11 - Inorganic chemical maximum contaminant levels and BATs
|
Contaminant |
MCL in mg/ L |
|
Antimony |
0.006 |
|
Arsenic |
0.010 |
|
Asbestos |
7 Million fibers/Liter |
|
(longer than 10 um) |
|
|
Barium |
2 |
|
Beryllium |
0.004 |
|
Cadmium |
0.005 |
|
Chromium |
0.1 |
|
Cyanide(as free Cyanide)0.2 |
|
|
Fluoride |
4.0 |
|
Mercury |
0.002 |
|
Nickel |
0.1 |
|
Nitrate |
10 (as Nitrogen) |
|
Nitrite |
1 (as Nitrogen) |
|
Total Nitrate Nitrite |
10 (as Nitrogen) |
|
Selenium |
0.05 |
|
Thallium |
0.002 |
|
Contaminant |
BAT(s) |
|
Antimony |
2,7 |
|
Arsenic4 |
1,2,5,6,7,9,125 |
|
Asbestos |
2,3,8 |
|
Barium |
5,6,7,9 |
|
Beryllium |
1,2,5,6,7 |
|
Cadmium |
2,5,6,7 |
|
Chromium |
2,5,62,7 |
|
Cyanide |
5,7,10,13 |
|
Mercury |
21,4,61,71 |
|
Nickel |
5,6,7 |
|
Nitrate |
5,7,9 |
|
Nitrite |
5,7 |
|
Selenium |
1,23,6,7,9 |
|
Thallium |
1,5 |
1 BAT only if influent Hg concentration.
2 BAT for Chromium III only.
3 BAT for Selenium IV only.
4 BATs for Arsenic V. Pre-oxidation may be required to convert Arsenic III to Arsenic V.
5 To obtain high removals, iron to arsenic ratio mus be at least 20:1.
Key to BATs in Table:
1 = Activated Alumina
2 = Coagulation/Filtration (not BAT for public water systems < 500 service connections)
3 = Direct and Diatomite Filtration
4 = Granular Activated Carbon
5 = Ion Exchange
6 = Lime Softening (not BAT for public water systems < 500 service connections)
7 = Reverse Osmosis
8 = Corrosion Control
9 = Electrodialysis
10 = Oxidation (Chlorine)
11 = Ultraviolet
12 = Oxidation/Filtration
13 = Alkaline Chlorination (pH >= 8.5)
Small Water System Compliance Technologies1 for Arsenic2
|
Small water system compliance technology |
Affordable for listed small water system categories3 |
|
Activated Alumina (centralized) |
All size categories |
|
Activated Alumina (Point-of-Use)4 |
All size categories |
|
Coagulation/Filtration5 3,301-10,000 |
501-3,300, |
|
Coagulation-assisted Microfiltration 3,301-10,000 |
501-3,300, |
|
Electrodialysis reversal6 3,301-10,000 |
501-3,300, |
|
Enhanced coagulation/filtration |
All size categories |
|
Enhanced lime softening (pH> 10.5) |
All size categories |
|
Ion Exchange |
All size categories |
|
Lime Softening5 3,301-10,000 |
501-3,300, |
|
Oxidation/Filtration7 |
All size categories |
|
Reverse Osmosis (centralized)6 3,301-10,000 |
501-3,300, |
|
Reverse Osmosis (Point-of-Use)4 |
All size categories |
1 Section 1412(b)(4)(E)(ii) of the Safe Drinking Water Act or SDWA specifies that small water system compliance technologies must be affordable and technically feasible for small systems.
2 Small water system compliance technology for Arsenic V. Pre-oxidation may be required to convert Arsenic III to Arsenic V.
3 Section 1412(b)(4)(E)(ii) of the Safe Drinking Water Act or SDWA specifies 3 categories of small water systems: (i) those serving 25 or more, but fewer than 501, (ii) those serving more than 500, but fewer than 3,301, and (iii) those serving more than 3,300, but fewer than 10,001.
4 When POU or POE devices are used for compliance, programs to ensure proper long-term operation, maintenance, and monitoring must be provided by the water supplier to ensure adequate performance.
5 Unlikely to be installed solely for arsenic removal. May require pH adjustment to optimal range if high removals are needed.
6 Technologies reject a large volume of water-may not be appropriate for areas where water quantity may be an issue.
7 To obtain high removals, iron to arsenic ratio must be at least 20:1.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.