010-4 Wyo. Code R. §§ 4-11 - Chemical Feeders
(a) Chemical
feeders shall:
(i) Be installed, maintained
and operated in accordance with the manufacturer's specifications;
(ii) Be installed:
(A) So the gas or solution is introduced
downstream from the filter and heater; and
(B) If possible, at a point lower than the
heater outlet fitting or according to the manufacturer's
instructions.
(iii)
Incorporate failure-proof features so the chemical cannot feed into:
(A) The pool, spa or similar
installation;
(B) The piping
system,
(C) The water supply
system; or
(D) The pool, spa and
similar installation enclosure if equipment or power fails.
(I) Chemical feed pumps shall be wired so
they cannot operate unless there is adequate return flow to properly disperse
the chemical throughout the pool, spa or similar installation as
designed.
(iv)
Be regulated to ensure constant feed with varying supply or back
pressure;
(v) Be designed to
prevent siphoning from the re-circulation system to the solution container and
to prevent siphoning of the chemical solution into the pool, spa or similar
installation; and
(vi) Have a
graduated and clearly marked dosage adjustment to provide flows from full
capacity to ten (10) percent of such capacity.
(A) The device shall be capable of continuous
delivery within ten (10) percent of the dosage at any setting; and
(B) Be provided with make-up water supply
lines to chemical feeder solution tanks that have an air gap or other
acceptable cross-connection control.