010-4 Wyo. Code R. §§ 4-13 - Re-Circulation Systems
(a) A public pool
shall:
(i) Have re-circulation and filtration
systems with piping, pumps, filters, disinfection and other equipment to
maintain the pool water quality as required by these Regulations.
(b) The system of pumps, filters,
disinfection facilities and other equipment shall be of adequate size to
re-circulate, filter and disinfect the entire volume of pool water in the
following maximum time intervals:
|
Pool Type |
Maximum Turnover Time in Hours |
|
General-Use or Limited-Use pool over 2,000 square feet (185.87m²) of surface area |
6 |
|
Limited-Use pool less than 2,000 square feet (185.87m²) of surface area |
8 |
|
Wading and plunge pool |
2 |
|
Spa |
1/2 |
|
Flotation tank |
A minimum of three (3) turnovers between users. Bather load = one (1) person per tank unit. |
; and
(i) Overflow
water shall not be less than fifty (50) percent of the total re- circulated
water.
(c) A flow meter
must be installed in all re-circulation systems and shall:
(i) Measure the flow in gallons per
minute;
(ii) Be mounted in
accordance with the manufacturer's recommendations; and
(iii) Be easily accessible and easy to
read.
(d) Pressure
gauges must be installed on the inlet and outlet of the filter.
(e) Spa pool recirculation systems shall be
separate from adjacent swimming pools.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.