010-4 Wyo. Code R. §§ 4-18 - Spa Outlets
(a) A spa outlet
shall be designed so that the pumping system complies with one of the
following:
(i) Two (2) outlets of equal pipe
diameter size designed so that:
(A) Neither
one of the two outlets be cut out of the suction line by a valve; or
(B) By other means which would prevent
entrapment of the bather on the suction orifices.
(ii) One antivortex drain:
(A) The antivortex drain shall not present a
tripping or stubbing hazard to the feet; and
(B) The diameter of the antivortex plate
shall be at least six (6) inches (15cm).
(iii) An open area of one-hundred forty-four
(144) square inches (928 cm²) or larger grate.
(b) All outlet grates, antivortex plates and
inlet fittings shall have tamper-proof screws; and
(i) Grates, vortex plates and inlet fittings
shall be in place whenever the spa is in use.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.