010-7 Wyo. Code R. §§ 7-2 - Bathhouse Requirements
(a) A bathhouse
shall:
(i) Meet the requirements of the
Uniform Plumbing Code;
(ii) Be
located within two-hundred (200) feet (60.96m) of the general-use swimming
pool;
(iii) Contain dressing rooms
and sanitary facilities, separate for each sex;
(iv) Have slip resistant and easy to clean
floors coved to a height of four (4) inches (10cm);
(v) Have interior wall and ceiling finishes
that are smooth, easy to clean and impervious to water;
(vi) Have shower stall floors that are
finished with non-slip, impervious surfaces;
(vii) Be kept clean, free of dirt, algae,
molds or other debris; and
(viii)
Have shower compartments with walls that are impervious to water to a height of
six (6) feet (1.83m) above the floor.
(A) In
shower compartments, an effective water-tight joint between the wall and the
floor shall be maintained; and
(B)
Glass bath or shower doors shall be made of approved safety glass.
(I) Wooden racks or duck boards over shower
floors are not permitted.
(ix) Have shielded light fixtures.