(a) An ignition
interlock service provider shall:
(i) Service
a device within 30 days after the initial installation and thereafter as
recommended by the manufacturer, but not to exceed 60 days.
(ii) Ensure that another device is
substituted whenever an installer removes a device for any reason.
(iii) Calibrate every installed device at
least every 60 days.
(b)
At each service visit, the ignition interlock service provider shall:
(i) Perform a calibration confirmation test
to verify that the device measures an approved reference sample within plus or
minus 0.005 grams per 210 liters of the known concentration of the reference
sample.
(A) If the result of the calibration
confirmation test is not within plus or minus 0.005 grams per 210 liters of the
known concentration of the approved reference sample, the service center
operator shall recalibrate the device.
(B) If the device fails the calibration
confirmation test after being recalibrated, the service center operator shall
ensure that a new device is installed.
(ii) Check that the device will permit a
driver to restart a vehicle within 5 minutes without taking another breath test
after the vehicle has stalled or been turned off.
(iii) Check the device for evidence of
tampering and circumvention. An ignition interlock service provider shall
document and photograph any perforations, cuts, or other evidence of possible
tampering.