045-6 Wyo. Code R. §§ 6-11 - Casing of Utility Lines
(a) The Department
does not require casing of pipelines crossing the highway R/W as long as heavy
wall thickness carrier pipe is used and the pipeline is cathodically protected.
(Also see Section on Pipelines).
(b)
For crossings of small diameter power, communications, or similar lines that
can not be pushed or bored underneath the roadway embankment, a metallic or
nonmetallic casing pipe of a wall thickness that can withstand highway loading
may be used.
(c) Casing pipe or
heavy wall thickness pipe shall extend at a minimum to the face of the bore/
receiving pit to allow for future dirt widening of the road embankment and
shall be of a wall thickness meeting the criteria for highway
loading.
(d) For casing of water,
sanitary sewer, and storm water pipelines see the stipulations in Chapters VI
and VII of this regulation.