053-2 Wyo. Code R. § 56.19024 - Retirement criteria
Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:
(a) The number of broken wires
within a rope lay length, excluding filler wires, exceeds either-
(1) Five percent of the total number of
wires; or
(2) Fifteen percent of
the total number of wires within any strand.
(b) On a regular lay rope, more than one
broken wire in the valley between strands in one rope lay length.
(c) A loss of more than one-third of the
original diameter of the outer wires.
(d) Rope deterioration from
corrosion.
(e) Distortion of the
rope structure.
(f) Heat damage
from any source.
(g) Diameter
reduction due to wear that exceeds six percent of the baseline diameter
measurement.
(h) Loss of more than
ten percent of rope strength as determined by nondestructive testing.