053-2 Wyo. Code R. § 56.6132 - Magazine requirements
(a) Magazines shall
be-
(1) Structurally sound;
(2) Noncombustible or the exterior covered
with fire-resistant material;
(3)
Bullet resistant;
(4) Made of
nonsparking material on the inside;
(5) Ventilated to control dampness and
excessive heating within the magazine;
(6) Posted with the appropriate United States
Department of Transportation placards or other appropriate warning signs that
indicate the contents and are visible from each approach, so located that a
bullet passing through any of the signs will not strike the magazine;
(7) Kept clean and dry inside;
(8) Unlighted or lighted by devices that are
specifically designed for use in magazines and which do not create a fire or
explosion hazard;
(9) Unheated or
heated only with devices that do not create a fire or explosion
hazard;
(10) Locked when
unattended; and
(11) Used
exclusively for the storage of explosive material except for essential
nonsparking equipment used for the operation of the magazine.
(b) Metal magazines shall be
equipped with electrical bonding connections between all conductive portions so
the entire structure is at the same electrical potential. Suitable electrical
bonding methods include welding, riveting, or the use of securely tightened
bolts where individual metal portions are joined. Conductive portions of
nonmetal magazines shall be grounded.
(c) Electrical switches and outlets shall be
located on the outside of the magazine.