053-3 Wyo. Code R. § 57.22307 - Methane monitors (II-A mines)
(a) Methane
monitors shall be installed on continuous mining machines, longwall mining
systems, bench and face drills, and undercutting machines used in or beyond the
last open crosscut.
(b) The
monitors shall-
(1) Give warning at 0.5
percent methane;
(2) Automatically
deenergize electrical equipment, except power to monitoring equipment
determined by MSHA to be intrinsically safe under 30 CFR part 18, and prevent
starting such equipment when methane levels reach 1.0 percent; and
(3) Automatically deenergize the equipment
when power to a sensor is interrupted.
(c) Sensing units of monitors shall be
positioned at a location which provides for the most effective measurement of
methane.