(a) There shall be
developed and maintained an effective fire prevention and protection program at
the job site.
(b) Such fire program
shall have the following requirements:
(i)
Fire fighting equipment shall not be tampered with and shall not be removed for
other than the intended fire fighting purpose,
(ii) Fire extinguishers and other fire
fighting equipment shall be suitably located and plainly labeled as to their
type and method of operation.
(iii)
Used cleaning rags and combustible waste material shall be kept to a minimum,
stored in closed metal containers and disposed of daily.
(iv) Access to exits or fire extinguishers
shall not be blocked or obscured by clothing, materials or equipment.
(v) Well cellars, well floors and ground
areas adjacent to derricks shall be kept free from accumulation of oil which
might create or aggravate fire hazards.
(vi) Fire protection and fire fighting
equipment shall be maintained in a serviceable condition at all
times.
(vii) Records shall be kept
showing the date fire extinguishers were last inspected, tested or refilled,
and by whom.
(viii) All fire
extinguishers shall be maintained, inspected and hydrostatically tested in
accordance with 1910-157 of the State of Wyoming Occupational Health
and Safety 1910 -General Rules and Regulations.
(ix) Every drilling rig shall have readily
accessible not less than four (4) approved (Underwriter's Laboratories, Inc. or
Factory Mutual Engineering Corp.) extinguishers, each with a minimum capacity
of twenty (20) pounds multi-purpose dry chemical, or equivalent rated material.
The above is minimum and many occasions may warrant more equipment of larger
size.
(a) CBM Natural Gas drilling rigs shall
have readily accessible not less than two (2) approved extinguishers with a
minimum capacity of twenty (20) pounds multi-purpose dry chemical.
(b) All drilling rig crew at the rig site
will be trained in the proper use of a multi-purpose fire extinguisher annually
to control or extinguish incipient stage fires.
(x) Carbon tetrachloride extinguishers shall
not be permitted.
(xi) Every
welding operation shall have a suitable extinguisher available.
(xii) Extreme caution shall be used with open
flames around oil and gas operations.
(xiii) Natural or liquefied petroleum gas
(LPG) shall not be used to operate spray guns or other pneumatic
equipment.