053-4 Wyo. Code R. § 75.1905 - Dispensing of diesel fuel
(a) Diesel-powered
equipment in underground coal mines may be refueled only from safety cans, from
tanks on diesel fuel transportation units, or from stationary tanks.
(b) Fuel that is dispensed from other than
safety cans must be dispensed by means of-
(1) Gravity feed with a hose equipped with a
nozzle with a self-closing valve and no latch-open device;
(2) A manual pump with a hose equipped with a
nozzle containing a self-closing valve; or
(3) A powered pump with:
(i) An accessible emergency shutoff switch
for each nozzle;
(ii) A hose
equipped with a self-closing valve and no latch-open device; and
(iii) An anti-siphoning device.
(c) Diesel fuel must
not be dispensed using compressed gas.
(d) Diesel fuel must not be dispensed to the
fuel tank of diesel-powered equipment while the equipment engine is
running.
(e) Powered pumps shall be
shut off when fuel is not being dispensed.