053-4 Wyo. Code R. § 75.313 - Main mine fan stoppage with person underground
(a) If a main
mine fan stops while anyone is underground and the ventilating quantity
provided by the fan is not maintained by a back-up fan system-
(1) Electrically powered equipment in each
working section shall be deenergized;
(2) Other mechanized equipment in each
working section shall be shut off; and
(3) Everyone shall be withdrawn from the
working sections and areas where mechanized mining equipment is being installed
or removed.
(b) If
ventilation is restored within 15 minutes after a main mine fan stops,
certified persons shall examine for methane in the working places and in other
areas where methane is likely to accumulate before work is resumed and before
equipment is energized or restarted in these areas.
(c) If ventilation is not restored within 15
minutes after a main mine fan stops-
(1)
Everyone shall be withdrawn from the mine;
(2) Underground electric power circuits shall
be deenergized. However, circuits necessary to withdraw persons from the mine
need not be deenergized if located in areas or haulageways where methane is not
likely to migrate to or accumulate. These circuits shall be deenergized as
persons are withdrawn; and
(3)
Mechanized equipment not located on working sections shall be shut off.
However, mechanized equipment necessary to withdraw persons from the mine need not be shut off if located in areas where methane is not likely to migrate to or accumulate.
(d)
(1)
When ventilation is restored-
(i) No one
other than designated certified examiners shall enter any underground area of
the mine until an examination is conducted as described in 75.360(b) through
(e) and the area has been determined to be safe. Designated certified examiners
shall enter the underground area of the mine from which miners have been
withdrawn only after the fan has operated for at least 15 minutes unless a
longer period of time is specified in the approved ventilation plan.
(ii) Underground power circuits shall not be
energized and nonpermissible mechanized equipment shall not be started or
operated in an area until an examination is conducted as described in 75.360(b)
through (e) and the area has been determined to be safe, except that designated
certified examiners may use nonpermissible transportation equipment in intake
airways to facilitate the making of the required examination.
(2) If ventilation is restored to
the mine before miners reach the surface, the miners may return to underground
working areas only after an examination of the areas is made by a certified
person and the areas are determined to be safe.
(e) Any atmospheric monitoring system
operated during fan stop- pages shall be intrinsically safe.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.