053-5 Wyo. Code R. § 77.1434 - Retirement criteria

Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs:

(a) The number of broken wires within a rope lay length, excluding filler wires, exceeds either-
(1) Five percent of the total number of wires; or
(2) Fifteen percent of the total number of wires within any strand;
(b) On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length;
(c) A loss of more than one-third of the original diameter of the outer wires;
(d) Rope deterioration from corrosion;
(e) Distortion of the rope structure;
(f) Heat damage from any source;
(g) Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement; or
(h) Loss of more than ten percent of rope strength as determined by nondestructive testing.