053-5 Wyo. Code R. § 77.1910 - Explosives and blasting; general
(a) Light and power
circuits shall be disconnected or removed from the blasting area before
charging and blasting.
(b) All
explosive materials, detonators, and any other related blasting material
employed in the development of any slope or shaft shall be stored, transported,
carried, charged, and fired in accordance with the provision of Subpart N,
"Explosives and Blasting," of this Part 77. Except as provided in paragraph (c)
of this section, all shots shall be fired from the surface.
(c) Where tests for methane have been
conducted and methane has not been found and only permissible blasting units
are being employed, shots may be fired from an upper level of the slope or
shaft.
(d) Except as provided in
paragraph (c) of this section, all men shall be removed from the slope or shaft
prior to blasting.
(e) Blasting
areas in slopes or shafts shall be covered with mats or other suitable material
when the excavation is too shallow to retain blasted material.
(f) Where it is impracticable to prepare
primers in the blasting area, primers may be prepared on the surface and
carried into the shaft in specially constructed, insulated, covered
containers.
(g) No other
development operation shall be conducted in a shaft or at the face of a slope
while drill holes are being charged and until after all shots have been
fired.
(h) The sides of the slope
or shaft between the overhead platform and the bottom where men are working
shall be examined after each blast and loose material removed.
(i) Loose rock and other material shall be
removed from timbers and platforms after each blast before men are lowered to
the shaft bottom.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.