055-4 Wyo. Code R. §§ 4-15 - Production Facilities and Natural Gas Facility Equipment and Flowline Abandonment
(a) An
Owner/Operator of a well or wells shall notify the Supervisor of all above and
below ground flowlines and vessels, including tanks, if the flowlines or
vessels are not used for a period of two (2) years. After consideration of the
relevant circumstances, the Supervisor on a case-by-case basis, may require the
flowline or facilities to be purged with fresh water or inert gases, drained
and depressured. The Owner/Operator shall provide notification of the purging
operation to the Supervisor or Authorized Agent.
(b) The Supervisor may require the Owner or
Operator to abandon and/or remove all above ground piping. If flowlines or
facility piping are removed, the removal shall be done in a manner that
prevents the escape of fluids, that is:
(i)
Purge with fresh water or inert gases, drain and depressure; then,
(ii) Seal the line or cap at both ends. If
not removed, the Owner or Operator will be required to mark remaining piping to
identify as purged piping.
(c) If underground flowlines or facility
piping are abandoned in place, the Owner or Operator shall meet the following
requirements:
(i) Purge with fresh water or
inert gases, drain and depressure the flowline and piping;
(ii) Seal the line or cap at both ends;
and,
(iii) Bury at least
twenty-four inches (24") below the surface and restore the surface contour,
unless the Supervisor or the surface land owner agrees otherwise in
writing.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.