10 CFR 429.46 - Commercial clothes washers.

§ 429.46 Commercial clothes washers.

(a)Sampling plan for selection of units for testing.

(1) The requirements of § 429.11 are applicable to commercial clothes washers; and

(2) For each basic model of commercial clothes washers, a sample of sufficient size shall be randomly selected and tested to ensure that -

(i) Any represented value of the water factor or other measure of energy or water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

Or,

(B) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and

(ii) Any represented value of the modified energy factor or other measure of energy or water consumption of a basic model for which consumers would favor higher values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

Or,

(B) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(b)Certification reports.

(1) The requirements of § 429.12 are applicable to commercial clothes washers; and

(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information:

(i) If testing was conducted using Appendix J1 to subpart B of part 430 of this chapter: The modified energy factor (MEF) in cubic feet per kilowatt hour per cycle (cu ft/kWh/cycle); and the water factor (WF) in gallons per cubic feet per cycle (gal/cu ft/cycle);

(ii) If testing was conducted using Appendix J2 to subpart B of part 430 of this chapter: The modified energy factor (MEFJ2) in cu ft/kWh/cycle and the integrated water factor (IWF) in gal/cu ft/cycle.

[ 76 FR 12451, Mar. 7, 2011; 76 FR 24777, May 2, 2011, as amended at 79 FR 71630, Dec. 3, 2014]

Title 10 published on 10-May-2017 03:48

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 10 CFR Part 429 after this date.

  • 2017-03-29; vol. 82 # 59 - Wednesday, March 29, 2017
    1. 82 FR 15457 - Energy Conservation Program: Test Procedures for Central Air Conditioners and Heat Pumps; Correction
      GPO FDSys XML | Text
      DEPARTMENT OF ENERGY, Office of Energy Efficiency and Renewable Energy
      Final rule; technical correction.
      Effective: March 29, 2017.
      10 CFR Parts 429 and 430

Pages