(a) Sampling plan for selection of units for testing.

(1) The requirements of § 429.11 are applicable to commercial clothes washers; and

(2) For each basic model of commercial clothes washers, a sample of sufficient size shall be randomly selected and tested to ensure that -

(i) Any represented value of the water factor or other measure of energy or water consumption of a basic model for which consumers would favor lower values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

Or,

(B) The upper 97 1/2 percent confidence limit (UCL) of the true mean divided by 1.05, where:

and

(ii) Any represented value of the modified energy factor or other measure of energy or water consumption of a basic model for which consumers would favor higher values shall be greater than or equal to the higher of:

(A) The mean of the sample, where:

Or,

(B) The lower 97 1/2 percent confidence limit (LCL) of the true mean divided by 0.95, where:

(b) Certification reports.

(1) The requirements of § 429.12 are applicable to commercial clothes washers; and

(2) Pursuant to § 429.12(b)(13), a certification report shall include the following public product-specific information:

(i) If testing was conducted using Appendix J1 to subpart B of part 430 of this chapter: The modified energy factor (MEF) in cubic feet per kilowatt hour per cycle (cu ft/kWh/cycle); and the water factor (WF) in gallons per cubic feet per cycle (gal/cu ft/cycle);

(ii) If testing was conducted using Appendix J2 to subpart B of part 430 of this chapter: The modified energy factor (MEFJ2) in cu ft/kWh/cycle and the integrated water factor (IWF) in gal/cu ft/cycle.

[76 FR 12451, Mar. 7, 2011; 76 FR 24777, May 2, 2011, as amended at 79 FR 71630, Dec. 3, 2014]

Title 10 published on 2015-01-01

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 10 CFR Part 429 after this date.

  • 2015-11-27; vol. 80 # 228 - Friday, November 27, 2015
    1. 80 FR 74020 - Energy Conservation Program: Test Procedures for Portable Air Conditioners
      GPO FDSys XML | Text
      DEPARTMENT OF ENERGY, 10 CFR Parts 429 and 430
      Supplemental notice of proposed rulemaking.
      DOE will accept comments, data, and information regarding this SNOPR, submitted no later than December 28, 2015. See section V, “Public Participation,” for details.
      10 CFR Part 429