40 CFR Appendix Table 2 to Subpart FFFF of Part 60 - Table 2 to Subpart FFFF of Part 60—Model Rule—Emission Limitations

Table 2 to Subpart FFFF of Part 60—Model Rule—Emission Limitations

As stated in § 60.3022, you must comply with the following:

For the air pollutant You must meet this emission limitation a Using this averaging time And determining compliance using this
method
1. Cadmium 18 micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part.
2. Carbon monoxide 40 parts per million by dry volume 3-run average (1 hour minimum sample time per run during performance test), and 12-hour rolling averages measured using CEMS b Method 10, 10A, or 10B of appendix A of this part and CEMS.
3. Dioxins/furans (total basis) 33 nanograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 23 of appendix A of this part.
4. Hydrogen chloride 15 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Method 26A of appendix A of this part.
5. Lead 226 micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part.
6. Mercury 74 micrograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Method 29 of appendix A of this part.
7. Opacity 10 percent 6-minute average (observe over three 1-hour test runs; i.e., thirty 6-minute averages) Method 9 of appendix A of this part.
8. Oxides of nitrogen 103 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Method 7, 7A, 7C, 7D, or 7E of appendix A of this part, or ANSI/ASME PTC 19.10–1981 (IBR, see § 60.17(h)) in lieu of Methods 7 and 7C only.
9. Particulate matter 0.013 grains per dry standard cubic foot 3-run average (1 hour minimum sample time per run) Method 5 or 29 of appendix A of this part.
10. Sulfur dioxide 3.1 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Method 6 or 6C of appendix A of this part, or ANSI/ASME PTC 19.10–1981 (IBR, see § 60.17(h)) in lieu of Method 6 only.

a All emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions.

b Calculated each hour as the average of the previous 12 operating hours.