40 CFR Appendix Table 3 to Subpart FFFF of Part 60 - Model Rule—Operating Limits for Incinerators

Table 3 to Subpart FFFF of Part 60—Model Rule—Operating Limits for Incinerators

As stated in § 60.3023, you must comply with the following:

For these operating parameters You must establish operating
limits
And monitoring using these minimum frequencies
Data measurement Data recording Averaging time
1. Charge rate Maximum charge rate Periodic For batch units, each batch. For continuous or intermittent units, every hour Daily for batch units or units complying with § 60.3033(d). 3-hour rolling for continuous and intermittent units. a
2. Combustion temperature Minimum combustion chamber operating temperature Continuous Every 15 minutes 3-hour rolling. a
3. Pressure drop across the wet scrubber or amperage to wet scrubber Minimum pressure drop or amperage Continuous Every 15 minutes 3-hour rolling. a
4. Wet scrubber liquor flow rate Minimum flow rate at inlet to the scrubber Continuous Every 15 minutes 3-hour rolling. a
5. Wet scrubber liquor pH Minimum pH at scrubber outlet Continuous Every 15 minutes 3-hour rolling. a
6. Dry scrubber sorbent injection Minimum injection rate of each sorbent Continuous Every 15 minutes 3-hour rolling. a
7. Electrostatic precipitator secondary electric power Minimum secondary electric power, calculated from the secondary voltage and secondary current Continuous Every 15 minutes 3-hour rolling. a
8. Bag leak detection system alarm time Alarm time <5 percent of the operating time during a 6-month period Continuous Each date and time of alarm start and stop Calculate alarm time as specified in § 60.3023(f).
9. Waste profile The amount of each waste category burned as a percentage of total waste burned on a mass basis Periodic For batch units, each batch. For continuous or intermittent units, every hour Calendar quarter.

a Calculated each hour as the average of the previous 3 operating hours.

[90 FR 27969, June 30, 2025]