49 CFR 179.201-8 - Sampling device and thermometer well.

§ 179.201-8 Sampling device and thermometer well.

(a) Sampling valve and thermometer well are not specification requirements. When used, they must be of approved design, made of metal not subject to rapid deterioration by lading, and must withstand a pressure of 100 psig without leakage. Interior pipes of the sampling valve must be equipped with excess flow valves of an approved design. Interior pipe of thermometer well must be closed by an approved valve attached close to fitting where it passes through the tank and closed by a screw plug. Other approved arrangements that permit testing thermometer well for leaks without complete removal of the closure may be used.

(b) [Reserved]

[Amdt. 179-10, 36 FR 21348, Nov. 6, 1971, as amended at 66 FR 45390, Aug. 28, 2001]

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.


United States Code

Title 49 published on 19-May-2018 04:47

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 49 CFR Part 179 after this date.

  • 2018-03-29; vol. 83 # 61 - Thursday, March 29, 2018
    1. 83 FR 13464 - Request for Information on Regulatory Challenges to Safely Transporting Hazardous Materials by Surface Modes in an Automated Vehicle Environment; Correction
      GPO FDSys XML | Text
      DEPARTMENT OF TRANSPORTATION, Pipeline and Hazardous Materials Safety Administration
      Request for information; correction.
      Interested persons are invited to submit comments on or before May 7, 2018. Comments received after that date will be considered to the extent practicable.
      49 CFR Parts 107, 171, 172, 173, 174, 177, 178, 179, and 180