CHAPTER 1.
AUTHORITY
Act 419 of 1977 created the Arkansas Manufactured Home Commission
and setfortli the powers and duties of the Commission, the Director and other
personnel of the Agency to: administer the Federal Manufactured Home
Construction and Safety Standards; promulgate and enforce state standards for
manufactured home installation; require certification and/or licensing of
manufacturers, retailers, installers and salespeople; and to promulgate and
enforce rules and regulations governing the construction and installation of
manufactured homes manufactured, sold or offered for sale in the state of
Arkansas.
The following rules and regulations pertaining to the
manufacture, sale and installation of manufactured homes are duly adopted and
promulgated by the Arkansas Manufactured Home Commission pursuant to the
authority expressly conferred by Act 419 of 1977 as amended.
Repealing Clause: All previous rules and regulations pertaining
to the manufacture, sale, and installation of manufactured homes are hereby
repealed.
CHAPTER 2.
DEFINITIONS
The following terms are defined for the purpose of these
regulations. No attempt is made to define ordinary words which are used in
accordance with the established dictionary meaning except when the word has
been loosely used and it is necessary to define its meaning as used in these
regulations to avoid a misunderstanding.
Because the purpose is to define terms rather than words, the
definitions are alphabetical using the first word of the term rather than by
the noun.
A.
Agency:
The Director of the Arkansas Manufactured Home Commission or other personnel
authorized to act on behalf of the Director.
B.
Anchoring: A combination
of external ties, cables, straps and ground anchors or alternative systems
certified by an engineer used to secure the home to the ground to resist
displacement and movement by natural forces.
C.
Auction: Means the
selling or offering for sale of manufactured homes to manufactured home
retailers or to the public, by a person, firm or corporation not otherwise
certified or licensed, in an auction or liquidation format or on
consignment.
D.
Certification: Means the act of certifying or a state of being
certified.
E.
Commission:
Means Arkansas Manufactured Home Commission.
F.
Defect means any defect
in the performance, construction, components or material of a manufactured
fiome tliat renders the manufactured home or any part thereof not fit for the
ordinary use for which it was intended.
G.
Director. IVIeans the
Director of the Arkansas IVIanufactured Home Commission.
H.
Federal Standards: means
the National Manufactured Housing Construction and Safety Standards Act of
1974(42 U.S.C. §§
5401 etseq) and applicable regulations
promulgated by the United States Department of Housing and Urban Development,
as and when adopted by the Commission.
I.
HUD: Means the U.S.
Department of Housing and Urban Development.
J.
Installation: means work
done to stabilize, support or anchor a manufactured home or to join sections of
a multi-section manufactured home when any such work is governed by regulations
adopted by the Commission.
K.
Installer. Means any person, firm or corporation not
otherwise certified, engaged in the business of installing manufactured homes
for himself or on behalf of any other person not certified under this
Act.
L.
Manufacturer Means any person who manufactures manufactured
homes.
M.
Multi-Section: Means more than one unit of a manufactured home
when joined together form a single entity, a livable home.
N.
Quality Control: Means
in-p!ant inspection by the manufacturer to assure that all units meet the
National Manufactured Housing Construction and Safety Standards and the
approved DAPIA Manual for each plant.
O.
Retailer Means any
person, firm or corporation in the business of accepting on consignment, buying
for resale, selling or exchanging manufactured homes or offering same to the
public for sale, exchange or lease-purchase, whether for himself or on behalf
of any other person not certified as a retailer under this Act.
P.
Revocation: Means the
repeal or reversal of the rights of the manufacturer or retailer to sell or
distribute units in the State of Arkansas. Means the repeal or reversal of the
rights of the installer to set-up or anchor manufactured homes.
Q.
Salesperson: Means any
person employed by the retailer or manufacturer who is engaged in either the
wholesale or retail sale of manufactured homes.
R.
Separate Entity: Means
each individual location of a manufacturing plant or each individual retail
location.
S.
Site:
Means actual location of the manufactured home upon a plot of
ground.
T.
Standards:
Means the National Manufactured Housing Construction and Safety
Standards.
U.
Statement of
Compliance: Means tlie manufacturer or retailer certified and the
installer licensed by the Arkansas Manufactured Home Commission will comply
with Act 419 of 1977 as amended, the Arkansas Manufactured Home Commission's
rules and regulations, the National Manufactured Housing Construction and
Safety Standards Act of 1974 and the DAPIA Manual approved by HUD.
V.
Suspension: Means to
cease or stop temporarily the right to manufacture, sell, or install
manufactured homes within the State of Arkansas.
CHAPTER IV.
COMPLAINTS. INSPECTIONS AND DISPUTE
RESOLUTION
The Arkansas Manufactured Home Commission, in its capacity as a
state administrative agency (SAA) under the Federal standards enforcement
program and under authority granted by Arkansas law, may investigate, make
determinations relating to, and require correction of noncompliances, defects,
serious defects and imminent safety hazards occurring in manufactured homes
manufactured or installed in the state of Arkansas.
Implementation of the Commission's inspection programs, complaint
resolution programs and dispute resolution programs shall be in accordance with
these regulations and applicable laws and regulations governing manufactured
homes.
Section 400.
Complaints Against Manufacturers, Retailers or
Installers
A.
Standard Forms Required; Information Requested
All complaints against manufacturers, retailers or installers
shall be submitted to the Commission on forms supplied by the Agency.
Information requested on the complaint form shall include, but not be limited
to;
1. Name and complete mailing
address of manufactured home owner;
2. Physical address of home, if different
from mailing address;
3. Telephone
number(s) of home owner;
4. Date of
purchase or installation;
5. Year
of manufacture and size of home;
6.
Name and location of manufacturer;
7. Name and location of retailer;
8. Name and location or installer, if
applicable; and
9. Specific items
of complaint.
Section
401.
Compliance With Subpart I of HUD
Regulations
A. All complaints
concerning units constructed in compliance with the National Manufactured
Housing Construction and Safety Standards Act of 1974 shall be handled in
compliance with Subpart I of the regulation established pursuant to the Act and
state regulations.
1. Upon receipt of a
consumer complaint or other information indicating the possible existence of a
noncompliance, defect, serious defect, or imminent safety hazard, the Arkansas
Manufactured Home Commission will review the complaint or information and
forward the complaint or other information to the manufacturer of the
manufactured home in question. When it appears from the complaint or other
information that more than one manufactured home may be involved, the complaint
will simultaneously be forwarded to HUD and to the SAA of the State where the
manufactured home was manufactured.
2. When the complaint is forwarded to the
manufacturer, the manufacturer will be requested, in writing, to investigate
the complaint within twenty (20) days after receipt of the information and
carry out any necessary investigations and inspections to determine whether the
manufacturer is responsible.
3.
Where the manufacturer has determined and reports that no imminent safety
hazard, serious defect, defect or noncompliance exists and the Arkansas
Manufactured Home Commission is able to concur from all available information,
the Commission will consider the complaint closed and so inform the
manufacturer and complainants; however, if the Commission is unable to concur
with the manufacturer's report, a SAA investigation will be made and a copy of
the investigation will be sent to the manufacturer and complainants. If it is
found that the manufacturer's report was correct, the Commission will consider
the matter closed.
4. Where, upon
investigation, the Commission deternnines that an imminent safety hazard,
serious defect, defect or noncompliance may exist, it will notify the
manufacturer and request the manufacturer to take necessary action. Where the
manufacturer does not take action after notification by the Arkansas
Manufactured Home Commission and it appears that an imminent safety hazard or
serious defect may exist, the Commission will inform the manufacturer of its
opinion and simultaneously forward to HUD documentation of the factual basis
upon which an opinion was made, for administrative determination by HUD,
pursuant to
24
C.F.R., Section
3282.407(a).
Where the manufacturer does not take action after notification by the Arkansas
Manufactured Home Commission and it appears that a defect or noncompliance may
exist, the Commission will so notify the manufacturer. The notice shall be sent
to the manufacturer by certified mail and will include:
(a) The preliminary determination by the
Arkansas Manufactured Home Commission;
(b) The factorial basis for the
determination;
(c) The identifying
criteria of the manufactured homes known to be affected;
(d) Notice to the manufacturer that a hearing
or presentation of views may be requested pursuant to 24 C.F.R. Part
3282, Subpart D, to establish that there is no such defect or
noncompliance;
(e) Notice to the
manufacturer that the preliminary determination shall become final unless the
manufacturer responds within fifteen (15) days after receipt of such notice and
requests a hearing or presentation of views; and
(f) Notice to the manufacturer that any
information upon which the determination has been based, such as test results,
records of inspection, etc., shall be available for inspection by the
manufacturer.
5. Where
the manufacturer requests a hearing or presentation of views, one shall be held
pursuant to
24 C.F.R. Section
3282.152.
6. Where the manufacturer fails to respond to
the notice of preliminary determination or if the Arkansas Manufactured Home
Comnnission decides that the views and evidence presented by the manufacturer
or others are insufficient to rebut the preliminary determination, the
Commission may make a final determination that a defect or noncompliance exists
and will notify the manufacturer to make a notification and submit a plan in
accordance with
24 C.F.R. Section
3282.409. Within ten (10) days after receipt
of the notice of final determination, the manufacturer may appeal to the
Secretary of the United States Department of Housing and Urban
Development.
7. The manufacturer's
plan for notification and correction, including contents of notice, time for
implementation and completion of actions and reports, shall be made in
accordance with the provisions of
24 C.F.R. Section
3282.409 through
3282.413.
When the manufactured home is in the hands of a distributor or retailer, it
shall be handled in accordance with
24
C.F.R. Section
3282.414.
SECTION 402.
Notification and
Correction Procedures Required of Manufacturers and
IP!AS.
A.
Manufacturer's
Determination.
When a consumer complaint is referred to the manufacturer and the
manufacturer determines that an imminent safety hazard, serious defect, defect
or noncompliance may exist and the manufacturer does not correct the imminent
safety hazard or failure to conform within thirty (30) days of the date on
which the manufacturer determined the existence of an imminent safety hazard or
failure to conform, the manufacturer shall prepare and submit a plan as
provided for in
24 C.F.R. Section
3282.409, to the Arkansas IVIanufactured Home
Commission.
B.
Notification.
Tlie plan, including a copy of the Notice as required by
24 C.F.R. Section
3282.410, shall be submitted to the Arkansas
Manufactured Home Commission by the manufacturer and shall provide for
notification by mail, to the first purchaser of each manufactured home
containing an imminent safety hazard, serious defect, defect or noncompliance
and any subsequent purchaser to whom any warranty provided by the manufacturer
or required by Federal, State or Local Law has been transferred, to the extent
feasible; by mail to any other person who is a registered owner of each
manufactured home containing an imminent safety hazard, serious defect, defect
or noncompliance and whose name has been ascertained pursuant to 24 C.F.R. Section 3282.211.
C, Review.
1. The Arkansas Manufactured Home Commission
will review the plan submitted by the manufacturer, including the contents of
the notice and either approve the plan as submitted or make modifications to
the plan for compliance with the requirements of
24 C.F.R. Section
3282.409 and notify the manufacturer of the
approval or modification. The manufacturer may contest the modification within
five (5) days of the approval of the plan of modification.
2. If the Arkansas Manufactured Home
Commission does not accept the manufacturer's position as to the modification,
it shall act as follows:
(a) If the
manufacturer contends that the manufactured home contains a defect rather than
an imminent safety hazard or serious defect as the Arkansas Manufactured Home
Commission contends, the Arkansas Manufactured Home Commission shall refer the
matter to the Secretary /for determination under
24
C.F.R.
3282.407(a).
3. The formal notification
requirements which would result from any determination by the manufacturer
under
24 C.F.R.
Section
3282.404 may be waived by the
Commission that would othenwise review the plan upon receipt of satisfactory
assurances from the manufacturer that:
(a) The
manufacturer has identified the class of possibly affected manufactured homes
in accordance with
24 C.F.R. Section
3282.409;
(b) The manufacturer will correct at the
manufacturer's expense, all affected manufactured homes; and
(c) The repairs, in the Commission's
judgment, are adequate to remove the imminent safety hazard or failure to
conform.
Section 403.
Compliance Witti
Federal Construction and Safety Standards Program
A. All manufactured homes manufactured in the
State, sold, or offered for sale in this state, shall be in strict compliance
with the Standards.
1. A HUD Certification
label will be affixed to the home as required.
2. The retailer shall inspect every new
manufactured home unit prior to selling to determine that all appliances,
fixtures and systems are not damaged and are in place and operable.
3. Whenever a retailer finds a nonconformance
or an imminent safety hazard in a manufactured home, the retailer shall contact
the manufacturer, provide full information concerning the problem, and request
appropriate action by the manufacturer. No retailer may sell a new manufactured
known by the retailer not to be in conformance with the Standards.
4. If a retailer alters a manufactured home
in such a way as to create an imminent safety hazard or to create a condition
which causes a failure to conform with applicable Federal Standards, the
manufactured home may not be sold, leased or offered for sale. Retailers shall
maintain complete records of all alterations or corrections of failures to
conform or imminent safety hazards made to homes.
B. The manufacturer's quality assurance
program shall be set forth by the plant's Design Approval Primary Inspection
Agency (DAPIA) and its quality assurance manual, and will be monitored by the
plant's Production Inspection Primary Inspection Agency (IPIA).
C. All plans, specifications and engineering
data shall be approved by a qualified Design Approval Primary Inspection Agency
(DAPIA) which has been approved by HUD.
Section 404.
Complaints and
inspections Under State Authority
A.
Consumer Complaints
This section establishes procedures for the investigation and
timely resolution of construction or installation defects in manufactured homes
that are reported to the Commission during the one-year period beginning on the
date of installation of the home, including:
1. Violations of the National Manufactured
Home Construction and Safety Standards Act of 1974, 42 U.S.C.
5401-
5425 or
regulations promulgated by the United States Department of Housing and Urban
Development; and
2. Violations of
the rules and regulations governing the installation of manufactured homes
promulgated by the Commission.
B.
Dispute Resolution
This section establishes procedures for the investigation and
timely resolution of disputes among manufacturers, retailers and installers of
manufactured homes regarding responsibility for the correction or repair of
construction or installation defects in manufactured homes that are reported to
the Commission during the one-year period beginning on the date of installation
of the home.
C.
Receipt of Complaint; Notice Required
Upon receipt of a consumer complaint or other information
indicating the possible violation of any provision of the Code or the rules and
regulations promulgated thereunder, the Agency shall review the complaint or
information and forward the complaint or other information to the manufacturer,
retailer and installer of the manufactured home in question.
D.
Corrective Action and Dispute
Resolution
When the complaint is forwarded, the manufacturer, retailer and
installer will be requested, in writing, to investigate the complaint within
twenty (20) days after receipt of the information and to carry out any
necessary investigations and inspections to determine the origin of the
complaint.
1. When, upon investigation
or inspection, the manufacturer, retailer or installer finds a violation of the
Code or the rules and regulations promulgated thereunder, then the party
responsible for the violation shall take the appropriate corrective action and
notify the Agency of any actions taken to bring the home into compliance with
the Code or the regulations.
2.
When there is a dispute among the manufacturer, retailer and installer as to
which party is responsible for the violation, then the Agency shall schedule an
inspection of the home in order to determine the nature of the violation and
assign responsibility for corrective action. The Agency shall provide notice of
such an inspection, including information about the home in question and the
date and approximate time of the inspection, in writing, to the manufacturer,
retailer and installer.
E.
Inspection by Commission; Notice
Required
When the manufacturer, retailer or installer reports that
corrective action has been taken to bring the home into compliance with the
Code or the regulations, the Commission will consider the complaint closed and
so inform the manufacturer, retailer or installer and the complainants;
however, when items included on the original complaint remain unresolved, the
Commission may schedule an inspection of the home in order to determine the
nature of the violation, if any, and assign responsibility for corrective
action. The Commission shall provide notice of such an inspection, including
information about the home in question and the date and approximate time of the
inspection, in writing, to the manufacturer, retailer and installer.
F.
Determinations by
Commission; Time Frame for Corrective Action
A copy of the Agency's inspection report, including
determinations of unresolved items and responsibility for corrective action
will be sent to the manufacturer, retailer, installer and the complainants. In
the report, the Director may order the manufacturer, retailer or installer to
correct the violation within a reasonable time, not to exceed ninety (90) days.
Should the Director determine that the violation poses a serious threat to the
health and safety of the purchaser of the home, the Director may order the
manufacturer, retailer or installer to correct the violation within five (5)
working days.
A manufacturer, retailer or installer may request additional time
to correct the violation. The request must be made in writing, and may be
granted by the Director only when the extension will not pose a serious threat
to the health and safety of the purchaser of the home.
G.
Appeal of Agency's
Determination
Should a manufacturer, retailer or installer dispute any
determination made by the Director or Agency staff, the manufacturer, retailer
or installer may appeal that determination to the Manufactured Home Commission.
Such an appeal must be received by the Agency in writing, postmarked not more
than ten (10) days following receipt of a determination issued by the Director.
The determination will be held in effect until a timely hearing by the
Commission or a Sub-Committee of the Commission. The Chairman of the Commission
may stay the determination after review of the facts pending the
hearing.
H.
Closing
of Complaints
1. When the
manufacturer, retailer or installer reports that corrective action ordered by
the Director has been taken to bring the home into compliance with the Code or
the regulations, the Commission will consider the complaint closed and so
inform the manufacturer, retailer or installer and the complainants.
2. When the manufacturer, retailer or
installer reports that the purchaser refuses to allow corrective action as
ordered by the Director to bring the home into compliance with the Code or the
regulations, the Commission will consider the complaint closed and so inform
the manufacturer, retailer or installer and the complainants.
/. Administrative Action by Commission; Notice of Hearing
Required; Penalties
1. When
items included in the Agency's inspection report remain unresolved, the
Commission may schedule a hearing to consider administrative action against the
manufacturer, retailer or installer. The Commission shall provide notice of
such a hearing, including information about the home in question and the date
and approximate time of the hearing, in writing, to the manufacturer, retailer
and installer.
2. The Commission
shall have the power to suspend, revoke, or refuse to renew the license or
certification under this chapter of any person who is found to have been guilty
of violating any provision of the Code or the rules or regulations promulgated
thereunder.
3. In lieu of
suspension, revocation, or refusal to renew a license or certification, the
Commission shall have the authority to impose a monetary penalty not to exceed
one thousand dollars ($1,000) for each violation and may suspend, refuse to
renew, or revoke the license or certification until the penalty is paid to the
commission. Such a penalty shall be imposed only if the Commission formally
finds that the public welfare would not be impaired by the imposition of a
monetary penalty rather than suspension, refusal to renew, or revocation and
that payment of same should achieve the desired disciplinary purpose.
4. Each violation of the Code or any
regulation or order issued pursuant to it shall constitute a separate violation
with respect to each manufactured home or with respect to each failure or
refusal to allow or perform an act required thereby.
J.
Appeal of Commission
Decision or Penalty
Should a manufacturer, retailer or installer dispute any decision
made or penalty imposed by the Commission, the licensee may appeal that
decision to the Circuit Court in accordance with the Arkansas Administrative
Procedure Act. Such an appeal shall stay that portion of the Commission order
which directs corrective action or the payment of any penalty. The licensee
shall not be required to act on the decision until such time as a final order
of the Circuit Court, Court of Appeals or Supreme Court is issued.
Section 405.
Inspections and Fee Structure
The Director of the Arkansas Manufactured Home Commission, with
the approval of the Commission, shall establish inspection and monitoring fees,
and provide for participation in the fee distribution system.
A.
State Label Fee
Beginning October 1, 2007, there shall be a fee of $50.00 per
home for each new manufactured home shipped into the State of Arkansas. This
fee shall be paid to the Commission by the home manufacturer. Manufacturers
shall also file a report of ail manufactured homes shipped into the state per
month. This report shall be filed on a form provided by or approved by the
Commission. Shipment reports and payment of required fees shall be made no
later than the 15th day of the month following the reporting period. It shall
be a violation of these regulations for a manufacturer to fail to comply with
the provisions of this paragraph.
B.
Installation Permit Fee and Random
Sample Compliance Assurance Inspections
Beginning October 1, 2007, licensed installers and installing
retailers shall be required to affix an installation permit decal to each new
manufactured home installed in the State. Permit decals shall be purchased from
the Commission and affixed to the home at the point where electrical power is
connected to the home. Permit decals shall be affixed to the home within ten
(10) days of delivery to the site.
There shall be a fee of $10.00 per each installation permit
decal. This fee shall be paid to the Commission by the home installer.
Installers and installing retailers shall also file a report of all new homes
installed in the state per month. This report shall be filed on a form provided
by or approved by the Commission. Installation reports and shall be made no
later than the 15th day of the month following the reporting period. It shall
be a violation of these regulations for an installer or installing retailer to
fail to comply with the provisions of this paragraph.
The Commission shall approve a procedure for the timely
inspection and certification of a percentage of the initial installations of
new manufactured homes installed in the state on a random-sample basis to
assure compliance with installation standards adopted by the Commission. The
percentage of homes inspected shall be set by the Commission, and shall be
determined based on requirements of the Federal Standards program, as and when
adopted by the Commission. The procedure shall place priority on inspecting
homes installed in all regions of the state by all participating installers and
installing retailers on a fair and equitable basis.
Compliance assurance inspections may be scheduled without notice.
Defects found in compliance assurance inspections may be processed in
accordance with these regulations, beginning with Section
404(F).
Determinations made by an authorized representative of the Commission may be
appealed in accordance with Section
404(G).
C.
Initial 100% Inspection
Fees/Certification
There shall be a fee of $30.00 per hour for conducting initial
100% inspections at manufacturer locations when the Commission acts as a
Production Inspection Primary Inspection Agency for the purpose of certifying
the manufacturer as required under Title VI of the Housing and Community
Development Act of 1974. This fee shall be paid to the Commission by the
manufactured housing manufacturer for whom the inspection is conducted. The
manufacturer shall also be charged for reimbursement of mileage and per diem
incurred by Commission personnel to and from the location of the
manufacturer.
The above procedures will be followed in the event it becomes
necessary to withhold HUD labels from the manufacturer because of continued
failures to comply with the approved design or when there is evidence that the
manufactured housing manufacturer is not performing under its approved quality
control manual.
D.
Plant Inspection Fee
There shall be a fee of $25.00 per unit for the inspection of all
manufactured homes manufactured within the State of Arkansas. This fee shall be
paid to the Commission. The manufacturer shall also be charged for
reimbursement of mileage and per diem incurred by Commission personnel to and
from the location of the manufacturer.
E.
Special Request for
Inspection.
When requests are made for inspections other than the regular
monitoring plant inspections, a fee of $30.00 per hour shall be charged to the
manufacturer and paid to the Commission. The manufacturer shall also be charged
for reimbursement of mileage and per diem incurred by Commission personnel to
and from the location of the manufacturer.
F.
Increased Frequency Inspection
Fee
There shall be a fee of $25.00 per unit for each reinspection for
increased frequency inspections. An increased frequency inspection shall be
scheduled by the Commission when inspections at a manufacturing facility reveal
repeated failures to conform to the approved designs or when there is evidence
that the manufactured home manufacturer is not performing under its approved
quality control manual. The Commission may advise the manufacturer prior to the
date of the scheduled inspection and the manufacturer shall comply with
instructions, if any, relative to the increased frequency inspection. The
manufacturer shall also be charged for reimbursement of mileage and per diem
incurred by Commission personnel to and from the location of the
manufacturer.
G.
Monitoring Inspection Fee
There shall be a fee established by the Secretary of the
Department of Housing and Urban Development in compliance with
24
C.F.R. 3282.302(b)(6) to be
paid by each manufacturer in this state for each manufactured home produced in
this State. The monitoring inspection fee shall be distributed according to
federal regulations.
H.
Other Special Inspections
When special inspections are requested by an unlicensed or
uncertified person or company, a fee of twenty dollars ($20.00) per hour may be
charged to the company or person requesting the inspection and paid to the
Commission. The company or person shall also be charged for reimbursement of
mileage and per diem incurred by Commission personnel to and from the location
of the inspection.
CHAPTER VI.
INSTALLATION AND ANCHORING
SPECIFICATIONS
Section
600.
Installation Standards for New Homes, Used
Homes
The Arkansas IVIanufactured Home Commission by regulation shall
set uniform reasonable standards for the proper initial installation of new
manufactured homes installed in this state, provided that such installation
standards equal or exceed installation standards promulgated under the Federal
standards
The commission by regulation shall set uniform reasonable
standards for the proper secondary installation of used manufactured homes
installed in this state.
The person, firm or corporation providing the installation of a
manufactured home shall be responsible for making sure the installation and
anchoring of such manufactured home meets the manufacturer's installation
requirements or the Commission's installation regulations, as follows:
A.
New Manufactured Homes
New single section and multi-section manufactured homes shall be
installed according to the manufacturer's installation instructions.
B.
Used Manufactured
Homes
Used single section and multi-section manufactured homes shall be
installed according to the Arkansas Manufactured Home Commission's installation
specifications, as set forth in these regulations.
C.
Alternative Systems
Allowed
It is not the intent of these regulations to prohibit the
installation of any manufactured home in which the methods or materials used in
the installation of the support system meets or exceeds the requirements of the
manufacturer's installation instructions or the Arkansas Manufactured Home
Commission's installation specifications, as set forth in these regulations, as
related to foundation stability and/or load bearing capacity.
Section 601.
Elements of Installation
As used in these regulations, 'Installation' shall
include;
1. The requirements for
I-beam, center-line, and perimeter pier support columns and footings;
2. Marriage line, utility and other
cross-over connections {if applicable);
3. Anchoring systems and equipment, as
prescribed in the manufacturer's installation instructions or the Arkansas
Manufactured Home Commission's installation specifications; and
4. Any other installation requirements
outlined in the manufacturer's installation instructions for new homes or the
Arkansas Manufactured Home Commission's installation specifications for used
homes.
Section 602.
State Installation Specifications
A.
Site Preparation
1. All decayable materials, including grass,
leaves, roots and wood, shall be removed from under the locations of footings
and foundations. Manufactured home purchasers shall provide a site suitable for
the placement of a home.
2.
Footings and foundation base blocks shall rest on undisturbed or minimum ninety
percent (90%) compacted soil of uniform density and thickness or equivalent
base material.
3. Soil
classification and bearing capacity of the soil must be determined before the
foundation is constructed and anchored. Soil classification and bearing
capacity may be determined by one or more of the following methods, unless the
soil bearing capacity is established as permitted in (f) of this section:
a. Soil tests in accordance with generally
accepted engineering practices;
b.
Soil records of the applicable local authority having jurisdiction;
c. A pocket penetrometer; or
d. If soil classification or bearing capacity
cannot be determined by test or soil records, the classification, allowable
pressures and torque value shown in the table below may be used.
|
Soil Classification
|
|
Classification Number
|
ASTiVID 2478-00 or D 2488-00
|
Soil Description
|
Allowable Soil Bearing Pressure PSF
|
Blow Count ASTM D 1586-99
|
Torque Probe Value (inch-pounds)
|
|
1
|
Rock or Hard Pan
|
4000 +
|
|
2
|
GW, GP, SW, SP, GM, SM
|
Sandy Gravel & Gravel; Very Than Dense and/or
Cemented Sands; Course Gravel/Cobbles; Preloaded Silts, Clays &
Corals
|
2000
|
40 +
|
More Than 550
|
|
3
|
GC, SC, ML, CL
|
Sand; Silty Sand; Clayey Sands; Silty Gravel; Medim Dense
Course Sands; Sandy Gravel; and Very Stiff Silt, Sand Clays
|
1500
|
24-39
|
351-550
|
|
4A
|
CG. MH2
|
Loose to Medium Dense Sands; Firm to Stiff Clays &
Silts; Alluvial Fills
|
1000
|
18-23
|
276-350
|
|
4B
|
CH, MH2
|
Loose Sands; Firm Clays; Alluvial Fills
|
1000
|
12-17
|
175-275
|
|
5
|
OL, OH. PT
|
Uncompacted Fill; Peat; Organic Clays
|
0-11
|
Less Than 175
|
e. In
lieu of determining soil bearing capacity by use of the methods listed in this
section, an allowable pressure of 1000 pounds per square foot (psf) may be
used, unless the site-specific information requires the use of lower values
based on soil classification and type.
f. If the soil appears to be composed of
peat, organic clays or uncompacted fill, a registered geologist, registered
professional engineer or registered architect must determine the soil
classification and maximum allowable soil bearing capacity.
g. The installation shall not contribute to
ponding of water under the home.
B.
Pier Foundations -
Footings
1. The foundation
specifications contained in this section are not intended to address flood
loads or special site conditions. Consult the LAHJ or a registered engineer if
the home is to be located in a flood hazard area or has special site
considerations.
2. Support
foundations for each pier shall be concrete, either site buiit or pre-cast,
having minimum dimensions sixteen inches by sixteen inches by four inches
(16" X 16"x 4"). Other pier support materials may be used if
accepted by the manufacturer and the Commission.
3. The surface texture of poured concrete
footings at each pier location shall be such that the first pier block placed
at these locations shall sit firmly and evenly. If a firm, level contact
between the first pier block and the surface of the footing is not possible
because of surface irregularities in the footing; masonry mortar shall be used
between the entire bottom surface of the first pier block and the footing to
establish a solid interface contact which is level.
4. Pre-cast concrete footings {solid pad
blocks) shall be installed in a level position with the entire bottom surface
in contact with the site surface.
Click here
to view image
5.
Using the soil capacity, as described in Section
602(A)(3),
footings should be sized according to the table below.
FOOTER SIZING
TABLE
Based on Soil Bearing Capacity
|
Opening Size
|
1000 PSF
|
1500 PSF
|
2000 PSF
|
4000 PSF
|
|
4'-8'
|
400 sq in
|
256 sq in
|
256 sq in
|
256 sq in
|
|
8'-16'
|
576 sq in
|
400 sq in
|
256 sq in
|
256 sq in
|
|
16'-20'
|
784 sq in
|
576 sq in
|
400 sq in
|
256 sq in
|
|
20' - 28'
|
1156 sq in
|
784 sq in
|
576 sq in
|
256 sq in
|
|
i-Beam Footers (8' Max
Spacing)
|
576 sq in
|
400 sq in
|
256 sq in
|
256 sq in
|
C.
Piers - Support Columns
1.
Piers - General
Construction
a. All piers shall be
installed on footings or foundations and shall be centered under the I-beam.
All pier columns shall be centered on the footing or foundation.
b. No manufactured home piers shall be
located more than eight feet (8') apart on center. The first pier shall be
located within two feet (2') from either end of each I-beam.
c. The installation of foundations and piers
shall be constructed in a manner that shall demonstrate acceptable workmanship.
Each course of all piers shall be laid level and true to the vertical and
horizontal line.
d. Upon completion
of the pier support system, the manufactured home shall be reasonably level in
the longitudinal and side-to-side directions.
2.
Piers - Block
Requirements
Piers shall be constructed of eight inches by eight inches by
sixteen inches (8" x 8" X 16") concrete building blocks, open
celled, solid, or equivalent which meet or exceed the specifications per ASTM
C90, ground-contact rated. Open celled blocks shall be installed with the open
cells vertical.
3.
Piers - Height Regulations
a. No pier
shall be installed which is less than twelve inches (12") in
height.
b. Piers of three courses
of blocks or less shall be of single block construction. All piers of single
block construction installed under the main I-beam shall be installed
perpendicular to the I-beam.
c.
Piers that consist of more than three courses of blocks shall be of doubled
block construction and alternate courses shall be interlocking.
Click here
to view image
d.
When the total height of a support column, including footing pier blocks, and
wood, exceed fifty two inches (52"), the interlocking blocks
shall be filled with concrete and reinforced with three-eighths inch
(3/8") rebar.
e.
When the footings, piers and wood exceed eighty inches (80")
in height, the pier construction must be designed by a professional engineer or
architect and submitted to the Arkansas Manufactured Home Commission for
approval prior to installation.
4.
Piers - Cap Blocks, Top Plates and
Shims
Click here
to view image
a. A
combination of not more than two (2) solid concrete cap blocks
two inches (2"), three inches (3") or four
inches (4") by eight inches by sixteen inches {8"x
16") may be installed on top of the uppermost pier block. No
combination of cap blocks may exceed seven inches (7") in
height.
b. A two inches by eight
inches by sixteen inches (2"x 8" x 16") (nominal) pressure
preservative treated wood plate(s) shall completeiy cover the top of the
uppermost concrete building unit(s) of each pier.
c. Additional pressure preservative treated
w/ooden shims with a minimum width of five and one-half inches (5
1/2") and a minimum length of twelve inches (12") and
a minimum thickness of one-quarter inch (1/4") and a maximum
thickness of one inch (1") may be used between the wood plate
and the I-beam.
d. Hardwood wedges
with a minimum width of four inches (4") and a minimum length
of six inches (6") and a maximum installed thickness of one
inch (1") may be used if placed directly between the last
wooden member of the pier and the point of support. Wedges shall be centered
and driven tight from both sides of the I-beam or marriage line perimeter
joists.
5.
Piers - Marriage Line and Perimeter Blocking
a. The marriage line of multi-section
manufactured homes shall be supported by piers located no more than eight feet
(8') apart on center and shall have piers located within two
feet of each end of the marriage line. In addition to these piers,
multi-section homes shall have piers located under the jamb studs or ridge beam
column posts for openings in the marriage wall of four feet (4')
or greater.
b. Piers
shall also be located on each side of any exterior door, fireplace, bay window
or any other opening of forty-eight inches (48") or
more.
D.
Multi-Section Homes - Marriage Line and Utility Connections
1.
Multi-Section Homes - Sealing of
Marriage Line
a. All weatherproofing
material (fir strips, plastic or vinyl sheeting) shall be removed from floor
joints, marriage walls and end walls.
b. Sill sealer strips, expanding foam or
other insulating material shall be installed along the ceiling, floor and end
wall marriage lines to prevent air infiltration. Such strips or material (other
than foam) shall be secured in place with staples or nails.
c. Gaps between floor sections or ridge
beams, which do not extend the full length of the home, may not exceed two
inches (2") in width and must be sealed with plywood, lumber or other building
material. End wall marriage lines must be covered with exterior siding material
to resist the elements.
2.
Multi-Section Homes - Lag Bolting
and Roof Ridge Connections
a. Floor
sections shall be connected with lag bolts of at least five-sixteenths inch
(5/16"), and of sufficient length to penetrate into the
opposing floor joist at least three-quarters inch (3/4"). Lag
bolts shall be installed no more than twenty inches (20")
apart on center, alternating sides. Bolting must not dislodge the rim
joist.
b. Holes in bottom board
caused by lag bolt installation must be sealed.
c. The roof ridge shall be covered with ridge
cap or exterior roofing material to resist the elements and connected with:
1. Lag bolts installed no more than twenty
inches (20") apart on center, alternating sides, or
2. At least one and one-half inch
(11/2") twenty six gauge (26 Ga.) metal
straps or equivalent, secured with staples, nails or screws. A strap shall be
installed at each truss, extending at least six inches (6") on
each side of the ridge.
3.
Multi-Section Homes - Utility and Air Conditioning Cross-Over
Connections
a. All utility
connections made by the installing retailer or installer shall be protected
from weather or other elements.
b.
Electrical connections shall be made inside a junction box. Cross-over wiring
shall be covered with access panels or be protected by conduit attached with
clamps to junction boxes.
c. The
chassis of each section of the home shall be electncally bonded to one
another.
d. Air conditioning
cross-over ducts shall be attached to each plenum with screws and wire ties,
and taped to prevent air loss. The duct shall be suspended above the ground and
fastened in place. Ties or straps used to suspend the duct shall not crush or
crimp the duct in a manner that substantially reduces airflow.
Section 603.
Anchoring
Standards for New Homes, Used Homes
Anchoring is a mandatory requirement for any manufactured home
installed in the State of Arkansas.
A.
Anchoring - New Manufactured Homes
All new manufactured homes sold by certified retailers and
installed in the State of Arkansas shall be anchored according to the home
manufacturer's instructions. Manufacturers shall file with the Commission the
anchoring instructions as approved by the manufacturer's Design Approval
Primary Inspection Agency and shall provide prompt notification of changes,
modifications or updates relating to installation and anchoring.
B.
Anchoring - Used
Manufactured Homes
Used manufactured homes installed in the State of Arkansas shall
be anchored according to the Arkansas Manufactured Home Commission's anchoring
specifications, as set forth in this section.
C.
Alternative Systems
Aliowed
It is not the intent of these regulations to prohibit the
anchoring of any manufactured home in which the methods or materials used in
the anchoring system meets or exceeds the requirements of the manufacturer's
anchoring instructions or the Arkansas Manufactured Home Commission's anchoring
specifications, as set forth in these regulations, as related to resistance of
overturning or lateral movement as imposed by respective design loads. Such
alternative systems shall be certified by a professional engineer, architect or
nationally recognized testing laboratory as to their resistance to overturning
or lateral movement of the home.
Section 604.
State Anchoring
Specifications
A.
Anchoring Equipment
The following criteria shall be used In the anchoring of any
manufactured home installed in the state of Arkansas:
1. Anchoring equipment shall be capable of
resisting an allowable working load equal to or exceeding 3,150 lbs. and shall
be capable of withstanding a 50% overload {4,725 lbs. total) without failure of
either the anchoring equipment or the attachment point on the home. Ground
anchors shall be capable of resisting these loads in the soil in which the
anchors are installed.
2. Anchoring
equipment exposed to weathering shall have a resistance to weather
deterioration at least equivalent to that provided by a coating of zinc on
steel of not less than 0.30 ounces per square foot of surface coated.
3. Type 1, Finish B, Grade 1 steel strapping,
one and one-quarter inches (1-1/4") wide and 0.035 inch thick,
conforming with ATSM Standards Specification D3953-91 is judged to conform with
the provisions of this section and paragraph (1) of this section.
4. Cable used as tiedown straps shall be of
either galvanized steel or stainless. Steel cable shall be a minimum of
three-eighths inch (3/8") in diameter. Aircraft cable shall be
one-quarter inch (1/4") or larger in diameter.
5. Protection shall be provided at sharp
corners where the anchoring systems require the use of external cables or
straps.
6. Each manufactured ground
anchor shall be listed and installed in accordance with its listing and the
anchor manufacturer's instructions.
7. All anchors, straps, clips or other
components of anchoring must be new and may not be re-used.
S.
Anchoring -
Single Section Homes
1. All
single-section manufactured homes shall be anchored with diagonal anchoring
straps attached to the frame in addition to the anchoring of the home by means
of the over the top straps which may be supplied and built in by the
manufacturer. The number of diagonal frame anchors required shall be as
follows:
a. The diagonal frame anchors shall
be located no more than two feet (2') from either end of the
home on both I-beams and the additional anchors shall be located no more than
ten feet (10') apart along each I-beam.
b. Frame ties shall be installed according to
the component manufacturer's Instructions.
c. If eye bolts are utilized as the frame
attachment component, they shall be at least five-eighths inch (5/8")
in diameter and shall be bolted through the vertical portion of the
i-beam.
d. AN the vertical tie
straps that are built into the home by the manufacturer shall be used to anchor
the home in addition to the frame anchors which are required by this
section.
C.
Anciioring - Multi-Section
l-lomes
1. Multi-section manufactured
homes require only diagonal frame ties and anchoring. Such ties shall be
installed according to the manufacturer's DAPIA approved anchoring
instructions. In the case of used multi-section homes, the anchoring shall be
done according to the regulations and specifications set forth in this
section.
2. The number and spacing
of frame ties and anchors required for multi-section manufactured homes shall
be ased upon the length of the home and shall be the same spacing as that
specified or single-section manufactured homes in Section (B)(1)(a).
D.
Anchoring -
Installation of Ground, Rock and Concrete Anchors
1. Ail ground anchor systems and each
component as used in each ground system (soil, gravel, rock, etc.) shall be
capable of withstanding without failure a vertical and diagonal pull of 4,725
pounds at each tie for single-headed anchors or 9,450 pounds for double-headed
anchors. Any anchor installed shall be used in the ground system for which it
was designed and listed.
2. Ground
and rock anchors shall be at least eleven-sixteenths inch (11/16")
thick and be buried to a depth of at least three feet (3').
If longer anchors are used, they shall be buried to full
depth.
3. Concrete slab anchors
shall be installed according to the anchor manufacturer's instructions and
shall be capable of withstanding without failure a vertical and diagonal pull
of 4,725 pounds for each separate anchoring strap attached.
5. After the anchors have been properly
installed, all anchoring straps shall be tensioned according to the home
manufacturer's installation instructions or the anchor manufacturer's
instructions.
Click here
to view image
Click here
to view image