Fla. Admin. Code Ann. R. 40C-3.021 - Definitions
When used in this chapter:
(1) "Casing Diameter" or "diameter of casing"
means the largest nominal permanent water bearing casing. For the purposes of
this section, the diameter of the casing at the upper terminus will be presumed
to be the diameter for the entire length, unless the well owner or contractor
can demonstrate that the well has a smaller diameter permanent water bearing
casing below the upper terminus.
(2) "Confining Unit" means a body of
distinctly less permeable material stratigraphically adjacent to one or more
aquifers. "Intermediate" as used in paragraph
40C-3.517(4)(c),
F.A.C., refers to the materials and specifically carbonates that lie between
and collectively retard the exchange of water between the overlying surficial
aquifer system and the underlying Floridan aquifer system. The system
nomenclature is described in Florida Geological Survey Special Publication No.
28 (1986), which is incorporated by reference and available at (https://www.flrules.org/Gateway/reference.asp?No=Ref-07120)
and upon request from the St. Johns River Water Management District, 4049 Reid
Street, Palatka, FL 32177-2529.
(3)
"Consolidated" means a stratum which is cemented with a binding substance
commonly derived from within the deposit containing that stratum.
(4) "Consumptive Use Permit" means a permit
issued under Chapter 40C-2, F.A.C.
(5) "Contractor" means any person licensed by
the Department, or a water management district, in accordance with Chapter
62-531, F.A.C., and engaged in the business of construction, repair, or
abandonment of wells.
(6) "Driller"
means a person who actually constructs the well.
(7) "Field Log" means an accurate, written
documentation of all construction activities needed to fill out well completion
reports.
(8) "Filter Pack" means
sand or gravel that is uniform, clean, and siliceous. It is placed in the
annulus of the well between the borehole wall and the well screen.
(9) "Gang Well" means a system where two (2)
or more water wells are coupled together with a common header or
manifold.
(10) "Inspection Port"
means any opening in the well seal or casing wall not less than one-half inch
in diameter through which unobstructed access to the inside of the casing can
be obtained for measuring water levels.
(11) "Jetted Well" means a pipe meeting Rule
62-532.500, F.A.C., standards
with an attached well point or open ended screen. The well is installed in
unconsolidated formations by the washing action of a water jet.
(12) "Monitoring Well" or "Observation Well"
means a well used primarily to monitor hydrologic parameters such as water
levels or water quality.
(13)
"Packer" means a device placed within the well casing that seals the joint
between two pieces of casing, between the casing and screen, between one
formation or water bearing strata and another, or between the formation and the
casing.
(14) "Particulate Material"
means any small pieces or grains of naturally occurring sediments.
(15) "Public Water Supply Well" means a well
constructed for the purpose of supplying water to a public water system, as
permitted under Chapter 62-550 or 62-555 or Rule
64E-8.002, F.A.C.
(16) "Test Hole" or "Exploratory Well" means
any temporarily cased or uncased hole drilled, bored, cored, washed, or jetted,
the intended use of which includes obtaining data for engineering or for
geophysical or geological exploration, prospecting for minerals or products of
mining or quarrying, but not for the purposes of producing, disposing of, or
searching for water.
(17) "Upper
Terminus" means that portion of a well casing ending at land surface or within
an approved depth below land surface as described in subsection
40C-3.512(6),
F.A.C. Land surface is considered to be the ground elevation of the finished
grade at the well.
(18) "Well
Casing" means a pipe installed in a borehole or driven.
(19) "Well Completion" means termination of
all construction, repair or abandonment activities. Continuous absence of a
drill rig from the construction site for five or more days indicates that the
well is deemed completed by the driller, unless proper notification, such as a
telephone call, is given to a representative of the District.
(20) "Well Completion Report" means the form
that is incorporated by reference in paragraph
40C-3.036(9)(b),
F.A.C., which is completed and signed by a licensed water well
contractor.
(21) All definitions
contained in Chapters 62-531 and 62-532, F.A.C., are adopted and incorporated
by reference in subsections
40C-3.036(1)
and 40C-3.036(2),
F.A.C., respectively.
Notes
Rulemaking Authority 373.044, 373.113, 373.171 FS. Law Implemented 373.019, 373.303, 373.306, 373.308, 373.309 FS.
New 10-14-84, Amended 12-5-85, Formerly 40C-3.021, 40C-3.0021, Amended 9-17-89, 7-27-16, 5-7-18.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.