Fla. Admin. Code Ann. R. 40D-3.507 - Casing and Liner Pipe Standards
(1) Well
casing installed by driving shall not have less than the dimensions and weights
specified in subsection
62-532.500(1),
F.A.C.
(2) Well casing or liner
pipe set into place without driving shall not have less than the dimensions and
weights specified by subsection
62-532.500(1),
F.A.C.
(3) Telescoped casings may
be used provided that casings of different diameters are joined with an
appropriate overlap and any annular space including the overlapped section
shall be grouted in accordance with subsection
62-532.500(3),
F.A.C. (2-16-12) incorporated by reference in subsection
40D-3.037(1),
F.A.C. To prevent interchanges of water when multiple aquifers or zones are
penetrated, grout shall extend from the bottom of the casing to the top of the
innermost casing. The use of lead packers for this purpose is prohibited.
(a) A minimum overlap of ten feet and one
casing centralizer in the overlapping section shall be required for non-public
supply wells which are less than six inches in diameter.
(b) A minimum overlap of 20 feet and two
casing centralizers in the overlapping section shall be required for public
supply wells and all wells six inches or more in diameter.
(4) When any part of a well casing with an
outside diameter of four inches or larger is intended to be installed in a bore
hole which is larger in diameter than the inside diameter of the casing, the
annular space shall be filled from bottom to top with not less than a nominal
two inch thickness of neat cement grout. For those well casings with an outside
diameter of less than four inches, the minimum grout thickness shall be a
nominal one inch.
(5) Liners may be
used in a well provided that cross-connection of aquifers of significantly
differing water quality does not occur. Liners installed within a casing shall
meet the grouting and sealing requirements of subsection (4), above. Liners
installed for the purpose of sealing off caving material in an open borehole
are not required to be grouted. A liner installed for the purpose of repairing
a well may be overlapped into an existing casing provided it is joined with an
appropriate overlap and a watertight seal and provided that loss of artesian
pressure or cross connection of aquifers of significantly differing water
quality does not occur.
Notes
Rulemaking Authority 373.044, 373.113, 373.171, 373.309, 373.337 FS. Law Implemented 373.306, 373.308, 373.309 FS.
New 7-1-90, Amended 9-30-91, 12-31-92, 2-19-04, 7-12-15.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.