Fla. Admin. Code Ann. R. 62-610.571 - Setback Distances
(1) Setback
distances for injection facilities shall be established in accordance with Rule
62-610.521, F.A.C.
(2) Outfalls for surface water discharges
shall not be located within 500 feet of existing or approved (but not yet
constructed) potable water intakes within Class I surface waters.
(3) Where zones of discharge are allowed by
this part and by Rule
62-520.465, F.A.C., the zone of
discharge shall not extend closer than 500 feet to a potable water supply
well.
(4) A 1, 000-foot setback
distance from the injection well to potable water supply wells shall be
required for injection wells used for salinity barrier control, which are
subject to the requirements of subsection
62-610.562(4),
F.A.C.
(5) For potable water supply
wells that are not potable water wells, as described in Rule
62-521.200, F.A.C., the
Department shall approve smaller setback distances than those required by
subsections 62-610.571(3) and
(4), F.A.C., if the applicant provides an
affirmative demonstration in the engineering report that confinement exists
between the injection zone and the potable water supply well such that the
injection will not adversely affect the quantity or quality of water withdrawn
from the potable water supply well.
(6) Unless specifically stated otherwise, all
setback distances shall be measured horizontally.