Haw. Code R. § 11-265-1032 - Standards: Process vents
(a) The owner or
operator of a facility with process vents associated with distillation,
fractionation, thin-film evaporation, solvent extraction or air or steam
stripping operations managing hazardous wastes with organic concentrations at
least 10 ppmw shall either:
(1) Reduce total
organic emissions from all affected process vents at the facility below 1.4
kg/h (3 lb/h) and 2.8 Mg/yr (3.1 tons/yr), or
(2) Reduce, by use of a control device, total
organic emissions from all affected process vents at the facility by
ninety-five weight percent.
(b) If the owner or operator installs a
closed-vent system and control device to comply with the provisions of
subsection (a), the closed-vent system and control device must meet the
requirements of section 11-265-1033.
(c) Determinations of vent emissions and
emission reductions or total organic compound concentrations achieved by add-on
control devices may be based on engineering calculations or performance tests.
If performance tests are used to determine vent emissions, emission reductions,
or total organic compound concentrations achieved by add-on control devices,
the performance tests must conform with the requirements of subsection
11-265-1034(c).
(d) When an owner
or operator and the director do not agree on determinations of vent emissions
and/or emission reductions or total organic compound concentrations achieved by
add-on control devices based on engineering calculations, the test methods in
subsection 11-265-1034(c) shall be used to resolve the disagreement.
Notes