Ill. Admin. Code tit. 77, § 870.150 - Heating and Air Conditioning
All on-site installations of heating and air conditioning systems shall meet the equipment manufacturer's specifications, comply with local code, and be performed by qualified personnel approved or licensed by the local jurisdiction for this work, a licensed manufactured home installer or the homeowner.
a) Heating Equipment. The
heating systems for most homes are provided with the duct systems installed.
On-site installation consists of connecting the crossover duct for
multi-section homes. Crossover ducts for multi-section homes must be supported
aboveground, sealed to prevent air leaks and cut to length to avoid
kinks.
b) Air Conditioning
Equipment. Air conditioning equipment must be installed in accordance with the
manufacturer's specifications and comply with local codes. The maximum
electrical full load ampere draw for the desired air conditioning unit must not
exceed the home manufacturer's circuit rating. Any field-installed wiring
beyond the junction box must include a fused disconnect located within sight of
the condensing unit. The maximum fuse size is marked on the condenser data
plate. Charging of the air conditioning equipment must be performed by
qualified personnel. Condensation from the air conditioning equipment must not
drain underneath the home.
c)
Clothes dryer vents must exhaust outside the exterior of the home, or any
perimeter foundation or skirting. The exhaust duct must be adequately supported
and sealed. The installation of the duct must be in accordance with the
manufacturer's instructions.