Ill. Admin. Code tit. 77, § 890.650 - Water Closets
a) Public Use
1) Water closet bowls for public use shall be
the elongated type, and the seat shall be an antimicrobial plastic open-front
seat. Exception: Water closet bowls for public use may have closed-front seats
provided that the seat is encased with a continuous plastic sleeve capable of
providing a clean surface for every user.
2) The activating handle, button or mechanism
of the flush valve shall be at least 10 inches above the overflow rim of the
bowl and not more than 44 inches above the floor.
3) In schools that are not licensed by the
Illinois Department of Children and Family Services as day care centers or
homes, water closets provided for the use of children under five years of age
shall be of size and height suitable for children's use, either child or
juvenile type in accordance with ASME A112.19.2/CSA B45.1.
4) Water closets designed for institutional
use may be used in intensive care facilities and intensive coronary care
facilities provided that the water closet swings only horizontally and has an
integral trap. A water closet flushometer shall be used to flush the fixture.
The plans and specifications shall be submitted to the Department for approval
prior to installation, and approval will be in writing from the Department
provided that the requirements of this subsection (a) are met.
b) Water Closet Tanks. Water
closet tanks shall have a volume sufficient to properly flush the water closet
bowls with which they are connected.
c) Ballcocks. Ballcocks for flush tanks shall
be of the anti-siphon type, be properly installed, and have a provision for
trap refill.
d) Flushing Device.
The flush valve seat in all water closet tanks shall be 1 inch or more above
the flood level rim of the water closet bowl, with the exception of one-piece
water closets in accordance with ASME A112.19.2/CSA B45.1.
e) Flushometer Valve. Flushometer valves
shall comply with ASSE 1037. Flushometer valves shall be installed so that they
are readily accessible for repair. When the valve is operated, it shall
complete the cycle of operation automatically, opening fully and closing
completely under the service pressure. At each operation, the valve shall
deliver water in sufficient volume and at a rate that will thoroughly flush the
fixture and refill the fixture trap. Flush valve flow shall be regulated.
Protection against backflow shall be provided by an approved vacuum breaker
installed on the discharge side of the flushing valve. The bottom of the vacuum
breaker, or the critical level line shown on the vacuum breaker, shall be at
least 4 inches above the overflow rim of the bowl (see Section
890.1140(a) and
(b)). Not more than one water closet shall be
served by a single flushometer valve.
f) Seats. Water closets shall be equipped
with seats of smooth, non-absorbent material. All seats of water closets
provided for public use shall be an antimicrobial plastic material and an
open-front style, except that closed-front seats may be provided if the seat is
encased with a continuous plastic sleeve ensuring a clean surface for every
user. No water closet seat shall be more than 11/2 inches thick. Seats for
accessible water closets may be open or closed front, and may have a lid or not
have a lid.
g) A flushometer tank
(or pressurized flushometer valve in accordance with ASSE 1037) shall be used
only with a water closet bowl specifically designed for that type tank/flushing
device (i.e., in accordance with ASME A112.19.2/CSA B45.1) and when the flow
pressure at the fixture meets the manufacturer's minimum
recommendations.
h) Water closets
that rely on substances other than water for proper operation shall comply with
the Private Sewage Disposal Code. Privies and chemical toilets shall not be
used inside any building.
i) Bidet.
A bidet shall be equipped with hot and cold, tempered and cold, or tempered
water only. An atmospheric vacuum breaker shall be installed on the discharge
side of the flushing valve. The bottom of the vacuum breaker, or the critical
level line shown on the vacuum breaker, shall be at least 4 inches above the
overflow rim of the bidet.
j)
Prohibited Water Closets. Hopper-style water closets and water closets with
concealed couplings or submerged side inlets are prohibited. (See Appendix
F.Illustration A.)