(1)
Storage. Adequate storage will be provided to protect
equipment from physical, chemical and ultraviolet-ray damage. The storage area
will be secured against unauthorized entry.
(2)
Communications. There
will be:
a. A public address system in
operation during the hours of business.
b. A radio communication link between the
platform and the staff responsible for jumper registration, landing, and
recovery.
c. A means on site to
communicate with local emergency responders.
d. A clearly visible sign at the entrance to
the operating site setting forth medical restrictions for jumpers, the
minimum-age requirement of 18 years of age, and instructions for
jumpers.
(3)
Wind
meter. An anemometer will be installed in accordance with the
manufacturer's recommendations and in a location easily visible to the
staff.
(4)
Lighting. Adequate lighting will be provided at a site that
operates at any time during the period of one-half hour prior to sunset until
one-half hour after sunrise. At a minimum, the lighting system will be capable
of lighting the jump platform , the jump space and the landing area .
(5)
Fences. The operator
will use fences in compliance with ASTM 2291-14, Part 14, to limit access to
the site.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
(1) Storage. Adequate storage shall be provided to protect equipment from physical, chemical and ultraviolet-ray damage. The storage area shall be secured against unauthorized entry.
(2) Communications.
a. There shall be a public address system in operation during the hours of business.
b. A radio communication link shall be established between the platform and the staff responsible for jumper registration, landing, and recovery.
c. There shall be a means on site to communicate with local emergency responders.
d. A clearly visible sign shall be placed at the entrance to the operating site setting forth medical restrictions for jumpers, the minimum-age requirement of 18 years of age, and instructions for jumpers.
(3) Wind meter. An anemometer shall be installed in accordance with the manufacturer's recommendations and in a location easily visible to the staff.
(4) Lighting. Adequate lighting shall be provided at a site that operates at any time during the period of one-half hour prior to sunset until one-half hour after sunrise. At a minimum, the lighting system shall be capable of lighting the jump platform , the jump space and the landing area .
(5) Fences. The operator shall use fences in compliance with ASTM 2291-14, Part 14, to limit access to the site.