Mich. Admin. Code R. 400.2431 - Home environment
Rule 431.
(1) A
congregate facility shall be so constructed, arranged, and maintained as to
provide adequately for the health, safety, and well-being of
occupants.
(2) Furnishings and
housekeeping standards shall be such that a congregate facility presents a
comfortable, clean, and orderly appearance.
(3) All occupied rooms shall be of standard
lath and plaster construction or equivalent.
(4) The atmosphere and routine of the
congregate facility shall be such that a resident may spend the majority of his
nonsleeping hours out of the bedroom.
(5) Dining, bath, sitting, living, and
recreation rooms shall be maintained by an adequate central heating system or
its equivalent at a temperature range of 68-72 degrees Fahrenheit during
nonsleeping hours.
(6) A congregate
facility shall make adequate provision for laundering personal
laundry.
(7) A congregate facility
shall be equipped to provide an adequate amount of hot water for a resident's
use between the temperature range of 110-120 degrees Fahrenheit at the
fixture.
(8) A toilet, lavatory, and
bathing or showering facility shall be provided for each 8 adults in a
congregate facility including live-in staff and residents. At least 1 toilet
and lavatory shall be provided on each floor having resident
bedrooms.
(9) Bathrooms and toilet
facilities without windows shall have forced ventilation to the outside.
Bathroom windows used for ventilation shall open easily.
(10) Toilets, bathtubs, and showers shall
provide for individual privacy.
(11)
Floors, walls, and ceilings shall be finished so as to be easily cleanable, and
shall be kept clean and in good repair.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.