Mich. Admin. Code R. 408.16527 - Maintenance
Rule 6527.
(1) A
power source of a mill, calender or their auxiliary equipment to be repaired,
serviced or set up shall be locked out by each employee doing the work if
unexpected start up would cause injury. Residual pressure shall be relieved
before and during such work when maintenance is performed on a pressurized
system.
(2) A braking or safety
device for a mill or calender shall be inspected and tested weekly. The
stopping distances shall be measured and recorded. Where the braking action
does not meet or exceeds the requirements of
R
408.16542 and
R
408.16546, repairs or adjustments shall be made before
operation is resumed.