Minn. R. agency 144, ch. 4626, SEWAGE, pt. 4626.1190 - BACKFLOW PREVENTION.* 5-402.11
A. Except as specified in items B and, C, and
D, a direct connection must not exist between the sewage system and a drain
originating from equipment in which food, portable equipment, or utensils are
placed.P1
B.
Item A does not apply to floor drains that originate in refrigerated spaces
that are constructed as an integral part of the building.
C. If allowed by chapter 4714, a warewashing
machine may have a direct connection between its waste outlet and a floor drain
when the machine is located within 5 feet (1.5 meters) of a trapped floor drain
and the machine outlet is connected to the inlet side of a properly vented
floor drain trap.
D. If allowed by
chapter 4714, a warewashing or culinary sink may have a direct
connection.
Notes
Statutory Authority: MS s 31.101; 31.11; 144.05; 144.08; 144.12; 157.011