Ohio Admin. Code 3701:1-48-11 - Inspection and maintenance of radiographic exposure devices, transport and storage containers, associated equipment, source changers, and survey instruments
(A) The licensee shall perform visual and
operability checks on survey meters, radiographic exposure devices, transport
and storage containers, associated equipment and source changers before use on
each day the equipment is to be used to ensure that the equipment is in good
working condition, that the sources are adequately shielded, and that required
labeling is present. Survey instrument operability must be performed using
check sources or other appropriate means. If equipment problems are found, the
equipment must be removed from service until repaired.
(B) Each licensee shall have written
procedures for:
(1) Inspection and routine
maintenance of radiographic exposure devices, source changers, associated
equipment, transport and storage containers, and survey instruments at
intervals not to exceed three months or before the first use thereafter to
ensure the proper functioning of components important to safety. Replacement
components shall meet design specifications. If equipment problems are found,
the equipment must be removed from service until repaired.
(2) Inspection and maintenance necessary to
maintain the type B packaging used to transport radioactive materials. The
inspection and maintenance program must include procedures to assure that type
B packages are shipped and maintained in accordance with the certificate of
compliance or other approval.
(C) Records of equipment problems and of any
maintenance performed under paragraphs (A) and (B) of this rule must be made in
accordance with paragraph (G) of rule
3701:1-48-23 of the
Administrative Code.
Notes
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.04
Prior Effective Dates: 10/20/2002
Promulgated Under: 119.03
Statutory Authority: 3748.04
Rule Amplifies: 3748.06, 3748.07
Prior Effective Dates: 10/20/2002, 3/22/07